Controlled Mechanical Stimulation in the Treatment of Tibial Fractures
The DOI matches its Crossref record.
Abstract
Although it is known that the mechanical environment affects the fracture healing process, the optimal conditions for the different stages of healing have not been defined. In the present studies, the influence of applying a very short period of axial micromovement with defined characteristics to healing fractures has been studied both in simulated and clinical tibial fractures. The fracture healing process is seen to be acutely sensitive to small periods of daily strain applied axially within two weeks of fracture. There are boundaries of strain magnitude and force of application of applied movement that, if exceeded, inhibit the healing process. The application of appropriate applied strain to clinical tibial fractures at a time shortly after injury, when most patients would be very inactive, appears to enhance the healing process when using external skeletal fixation.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The optimal amount of axial interfragmentary movement (IFM) has been reported to be in the range of 0.4–0.5 mm, depending on the distance of the fracture gap (21, 22).”
From Methods to accelerate fracture healing – a narrative review from a clinical perspective (2024) · cites this paper as [21]
Citations
Cites
Still being checked.
Cited by
Claes, L. E., & Heigele, C. A. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00153-5 · Cited by 802
Effects of Mechanical Factors on the Fracture Healing Process
Claes, L. E., Heigele, C. A., Neidlinger-Wilke, C., Kaspar, D., Seidl, W., Margevicius, K. J., & Augat, P. (1998) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199810001-00015 · Cited by 705
Biomechanical testing of the LCP – how can stability in locked internal fixators be controlled?
Stoffel, K., Dieter, U., Stachowiak, G., Gächter, A., & Kuster, M. S. (2003) · Injury · doi:10.1016/j.injury.2003.09.021 · Cited by 657
Influence of size and stability of the osteotomy gap on the success of fracture healing
Claes, L., Augat, P., Suger, G., & Wilke, H. (1997) · Journal of Orthopaedic Research · doi:10.1002/jor.1100150414 · Cited by 549
Bone fracture healing in mechanobiological modeling: A review of principles and methods
Ghiasi, M. S., Chen, J., Vaziri, A., Rodriguez, E. K., & Nazarian, A. (2017) · Bone Reports · doi:10.1016/j.bonr.2017.03.002 · Cited by 485
Metadata
- Authors
- KENWRIGHT, J., & GOODSHIP, A. E.
- Affiliations
- Nuffield Orthopaedic Centre (GB)
- ORCID
- GOODSHIP, ALLEN E.
- Venue
- Clinical Orthopaedics and Related Research
- Published
- 1989-04
- Volume
- 241
- Issue
- 241
- Pages
- 36-47
- ISSN
- 0009-921X (ISSN-L)
- OpenAlex
- W2018626421
- Cited by
- 373
- References
- 0
- Citations by year
- 2026: 4 · 2025: 6 · 2024: 11 · 2023: 14 · 2022: 7 · 2021: 10 · 2020: 7 · 2019: 10 · 2018: 9 · 2017: 5 · 2016: 9 · 2015: 8 · 2014: 7 · 2013: 6 · 2012: 14
- FWCI
- 5.18
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Clinical Orthopaedics and Related Research (publishedVersion)
- PubMed (publishedVersion)
- UCL Discovery (University College London) (submittedVersion)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone fractures and treatments
- Health Sciences › Medicine › Surgery › Hip and Femur Fractures
- Health Sciences › Medicine › Surgery › Spinal Fractures and Fixation Techniques
- Keywords
- tibial fractures, fracture healing, mechanical stimulation, applied strain, external fixation, mechanical environment
- MeSH terms
- Animals, Biomechanical Phenomena, Bony Callus, Elasticity, Fracture Fixation, Humans, Minerals, Orthopedic Fixation Devices, Physical Stimulation, Sheep, Stress, Mechanical, Tibial Fractures, Wound Healing
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Controlled Mechanical Stimulation in the Treatment of Tibial Fractures. https://app.cochat.ai/papers/10.1097/00003086-198904000-00006
- The paper
- KENWRIGHT, J., & GOODSHIP, A. E. (1989). Controlled Mechanical Stimulation in the Treatment of Tibial Fractures. Clinical Orthopaedics and Related Research. https://doi.org/10.1097/00003086-198904000-00006
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.