The DOI matches its Crossref record.
Immune Responses to Allogeneic and Xenogeneic Implants of Collagen and Collagen Derivatives
Abstract
Whereas xenogeneic collagen has provided a safe and effective biomaterial for numerous medical applications, there are few instances in which data permit the correlation of the immunologic profile of well-defined devices with their clinical sequelae. A major exception is the use of injectable bovine dermal collagen for soft-tissue contour correction. The low incidence of hypersensitivity has been studied in the context of clinical efficacy and safety with several devices. The findings indicate that such immunity usually results in the manifestation of local symptoms of dermal inflammation at sites of treatment that resolve as the implant is resorbed by the host. In contrast, more immunogenic hemostatic agents may elicit a more frequent or vigorous immune response that is not clinically visible or relevant in that application. Recent experiences with collagen-based devices for the repair and regeneration of bone have also demonstrated that the presence of immunity to their collagenous or non-collagenous components does not necessarily predict adverse clinical sequelae. Indeed, numerous specific data indicate that this immunity can exist as an epiphenomenon with no effect on osteogenesis. To get a true composite picture of biocompatibility, significant steps must be taken to characterize biomaterials properly and to ensure that immunologic, clinical, histologic, and other pertinent laboratory data are viewed in relation to one another and not in isolation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Repair of bone defects using synthetic mimetics of collagenous extracellular matrices
Lutolf, M. P., Weber, F. E., Schmoekel, H. G., Schense, J. C., Kohler, T., Müller, R., & Hubbell, J. A. (2003) · Nature Biotechnology · doi:10.1038/nbt818 · Cited by 850
The inflammatory responses to silk films in vitro and in vivo
Meinel, L., Hofmann, S., Karageorgiou, V., Kirker-Head, C., McCool, J., Gronowicz, G., Zichner, L., Langer, R., Vunjak-Novakovic, G., & Kaplan, D. L. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.02.047 · Cited by 786
Evaluation of hydrogels for bio‐printing applications
Murphy, S. V., Skardal, A., & Atala, A. (2013) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.34326 · Cited by 543
Safety Profile for the Clinical Use of Bone Morphogenetic Proteins in the Spine
Poynton, A. R., & Lane, J. M. (2002) · Spine · doi:10.1097/00007632-200208151-00010 · Cited by 403
Silk biomaterials in wound healing and skin regeneration therapeutics: From bench to bedside
Chouhan, D., & Mandal, B. B. (2020) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.11.050 · Cited by 348
Metadata
- Authors
- DELUSTRO, F., DASCH, J., KEEFE, J., & ELLINGSWORTH, L.
- Venue
- Clinical Orthopaedics and Related Research
- Published
- 1990-11
- Volume
- 260
- Issue
- 260
- Pages
- 263-279
- ISSN
- 0009-921X (ISSN-L)
- OpenAlex
- W2047144232
- Cited by
- 210
- References
- 0
- FWCI
- 6.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Immune Responses to Allogeneic and Xenogeneic Implants of Collagen and Collagen Derivatives. https://app.cochat.ai/papers/10.1097/00003086-199011000-00043
- The paper
- DELUSTRO, F., DASCH, J., KEEFE, J., & ELLINGSWORTH, L. (1990). Immune Responses to Allogeneic and Xenogeneic Implants of Collagen and Collagen Derivatives. Clinical Orthopaedics and Related Research. https://doi.org/10.1097/00003086-199011000-00043
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.