Tibial External Fixation, Weight Bearing, and Fracture Movement
The DOI matches its Crossref record.
Abstract
Axial fracture movement and loading has been measured during weight bearing in 45 patients with tibial diaphyseal fractures treated with unilateral external skeletal fixation. Mean axial fracture displacement reached a maximum of 0.6 mm between seven and 12 weeks postfracture. Very little movement occurred during the first five weeks after fracture. A micromovement module attached to the fixator increased axial movement at the fracture site by 50% during walking. Weight bearing reached 75% of mean body weight by ten weeks after the fracture. Weight bearing was not decreased by any biofeedback mechanism. A randomized prospective clinical study of diaphyseal tibial fractures treated with external fixation showed a significant reduction in time to healing when micromovement was imposed. Controlled fracture site movement can be imposed very early after fixator frame application when mechanical stimulation may be most effective, and the active loading by the patient is least.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“mechanical axial micromovement applied via external fixators was shown in the 1980s and 1990s to shorten the time a fracture needed to heal by more than 20% in patients with tibial fractures (16, 17).”
From Methods to accelerate fracture healing – a narrative review from a clinical perspective (2024) · cites this paper as [17]
In the citing paper
“Another study in human patients showed a 6-week reduction in healing time (17), which corresponds to a 21% reduction (23 weeks of healing time with stimulation and 29 weeks without stimulation, in groups of 23 and 22 patients, respectively).”
From Methods to accelerate fracture healing – a narrative review from a clinical perspective (2024) · cites this paper as [17]
Citations
Cites
Still being checked.
Cited by
Items 101–137 of 137
Reconstructive surgery of the human tibia by use of external ring fixator and the Ilizarov method
Kristiansen, L. P. (2009) · Acta Orthopaedica · doi:10.1080/17453690610046576 · Cited by 5
Staged complete dynamisation of the Ilizarov fixator: the Chertsey experience
Jabbar, Y., Jeyaseelan, L. A., & Khaleel, A. M. (2011) · European Journal of Orthopaedic Surgery & Traumatology · doi:10.1007/s00590-010-0746-x · Cited by 4
Howard, C. B., Elishoov, O., Matan, Y., Mosheiff, R., & Liebergall, M. (2009) · Injury Extra · doi:10.1016/j.injury.2009.06.291 · Cited by 4
Erdem, S., Gür, M., & Kaman, M. O. (2018) · Bio-Medical Materials and Engineering · doi:10.3233/bme-181012 · Cited by 4
Kapadia, S. M., Gust, M. J., Alghoul, M. S., & Dumanian, G. A. (2013) · Plastic & Reconstructive Surgery Global Open · doi:10.1097/gox.0b013e31828c3215 · Cited by 3
Huang, G., Liu, G., Zhang, F., Gao, J., Wang, J., Chen, Q., Wu, B., Ding, Z., & Cai, T.-Y. (2017) · International Journal of Medical Sciences · doi:10.7150/ijms.19613 · Cited by 3
Asymmetrical fracture fixation: stability of oblique fractures is influenced by orientation
Metcalfe, A. J., Saleh, M., & Yang, L. (2004) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2004.09.003 · Cited by 3
Tetsworth, K. D., & Glatt, V. (2019) · Journal of Limb Lengthening & Reconstruction · doi:10.4103/2455-3719.265264 · Cited by 3
Regenerative Rehabilitation Strategies for Complex Bone Injuries
Nash, K. E., Ong, K. G., Gebreyesus, E. A., LaBelle, S. A., Weiss, J. A., Harrer, J. A., Willett, N. J., Leucht, P., & Guldberg, R. E. (2022) · Physiology in health and disease · doi:10.1007/978-3-030-95884-8_8 · Cited by 2
RADIOLOGY OF DEVICES FOR FRACTURE TREATMENT IN THE EXTREMITIES
Chew, F. S., & Pappas, C. N. (1995) · Radiologic Clinics of North America · doi:10.1016/s0033-8389(22)00424-9 · Cited by 2
The Biology of Fracture Repair and the Role of Dynamization
KENWRIGHT, J., & Richardson, J. (2000) · Springer eBooks · doi:10.1007/978-1-4471-0691-3_2 · Cited by 2
Self-citationBussewitz, B. W., Scott, R. T., Hyer, C. F., & Philbin, T. M. (2012) · The Journal of Foot & Ankle Surgery · doi:10.1053/j.jfas.2012.11.002 · Cited by 1
Mohammad-Saeed, M. A. (2005) · Basrah Journal of Surgery · doi:10.33762/bsurg.2005.57518 · Cited by 1
Transfocal Osteotomy to Treat Shear (Oblique) Non-union of Tibia
Lahoti, O., Abhishetty, N., & Al-Mukhtar, M. (2022) · Strategies in Trauma and Limb Reconstruction · doi:10.5005/jp-journals-10080-1555 · Cited by 1
Enzymatic Activities in Limb Muscles Subjected to External Fixation With Ring-hybrid Frames
Reznick, A. Z., Coleman, R., & Stein, H. (2007) · Orthopedics · doi:10.3928/0147-7447-20070401-06 · Cited by 1
Enhancement of Bone Healing through Mechanical Stimulation
Rosa, N. (2017) · Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT) · doi:10.34626/qznf-0x41 · Cited by 1
de Sousa, C. M. P. (2016) · Repository of UTAD (Universidad De Tras-os Montes e Alto Douro) · Cited by 1
On incorporating bone microstructure in macro- nite-element models
Donaldson, F. E. (2011) · Edinburgh Research Archive (University of Edinburgh) · Cited by 1
Interfragmentäre Bewegungen und Bodenreaktionsparameter im Verlauf der Frakturheilung
Streitparth, F. (2006) · edoc Publication server (Humboldt University of Berlin) · doi:10.18452/15479
SCREW-BONE INTERFACE MODELLING IN LOCKING PLATE FE MODELS
MacLeod, A. R., Pankaj, P., & Simpson, H. (2012) · Journal of Biomechanics · doi:10.1016/s0021-9290(12)70334-2
Evaluation of Limb Lengthening Techniques
Justin, D. F. (2004) · Springer eBooks · doi:10.1007/978-94-011-0541-5_10
Cattermole, H. (1995) · Durham e-Theses (Durham University)
Semirigid Waved Rod System for the Treatment of the Degenerative Lumbar Diseases
Wang, L., Lin, D., Zou, W., Liu, H., & Lian, K. (2017) · Clinical Spine Surgery A Spine Publication · doi:10.1097/bsd.0000000000000506
García‐Rey, E., & Gómez‐Barrena, E. (2018) · Springer eBooks · doi:10.1007/978-3-319-98596-1_4
Criterios biomecánicos de diseño de un nuevo sistema de fijación externa: Stronger®
Pastor, J. P., Clavijo, M. C., Dejoz, R., Serra, J. L. P., Vicente, C. M. A., & Vera, P. (1995) · Repository of Digital Objects for Teaching Research and Culture (University of Valencia)
Lechner, J. J. A. (2013) · University of Regensburg Publication Server (University of Regensburg) · doi:10.5283/epub.28996
Fink, B. (2001) · Hefte zur Zeitschrift Der Unfallchirurg · doi:10.1007/978-3-642-59521-9_4
Weight-Bearing Monitoring Devices in Lower Extremity Fractures: A Scoping Review
Robinson, J., Wang, A. W. T., & Stockton, D. J. (2025) · Orthopedic Research and Reviews · doi:10.2147/orr.s521013
Prospects for the use of radiolucent materials in the design of external fixation devices
Bionyshev-Abramov, L. L., Lukina, Y. S., Bulgakov, V. G., & Gavryushenko, N. S. (2025) · N N Priorov Journal of Traumatology and Orthopedics · doi:10.17816/vto642813
Auger, J. (2000) · Papyrus : Institutional Repository (Université de Montréal) · doi:10.71781/3774
Heipel, R. (2010) · Dokumentenrepositorium der RUB (Ruhr University Bochum)
Dynamic analysis of combined with internal fixation human leg long bone fractures
ERDEM, S. (2013) · DSpace - FIRAT (Fırat University)
Optimal Configuration of Uniplanar-Unilateral External Fixators in Tibia Fractures
Roseiro, L. M., & Neto, M. A. (2012) · International series on intelligent systems, control and automation: science and engineering · doi:10.1007/978-94-007-4722-7_43
Finite clements study of external fixator system for fracture healing
Choromański, W., Lesniewska, A., & Dobrzynski, G. (2006) · Zeszyty Naukowe Katedry Mechaniki Stosowanej / Politechnika Śląska
Biomechanics of Bone-Fracture Fixation by External Unilateral Mechatronic Ortopaedic Fixators
Choromański, W., & Lesniewska, A. (2010) · Machine Dynamics Research
Metadata
- Authors
- KERSHAW, C. J., CUNNINGHAM, J. L., & KENWRIGHT, J.
- Affiliations
- Leicester Royal Infirmary (GB)
- Corresponding author
- KERSHAW, CHRISTOPHER J.
- CUNNINGHAM, JAMES L.
- KENWRIGHT, JOHN
- ORCID
- CUNNINGHAM, JAMES L.
- Venue
- Clinical Orthopaedics and Related Research
- Published
- 1993-08
- Volume
- 293
- Issue
- 293
- Pages
- 28???36
- ISSN
- 0009-921X (ISSN-L)
- OpenAlex
- W2021521387
- Cited by
- 124
- References
- 0
- Citations by year
- 2025: 3 · 2024: 3 · 2023: 1 · 2022: 4 · 2021: 1 · 2020: 1 · 2019: 2 · 2018: 3 · 2017: 6 · 2015: 5 · 2014: 5 · 2013: 7 · 2012: 7
- FWCI
- 2.14
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Clinical Orthopaedics and Related Research (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone fractures and treatments
- Health Sciences › Medicine › Surgery › Spinal Fractures and Fixation Techniques
- Health Sciences › Medicine › Surgery › Hip and Femur Fractures
- Keywords
- tibial shaft fractures, external fixation, weight bearing, fracture healing time, mechanical stimulation, biofeedback
- MeSH terms
- Bony Callus, Fracture Fixation, Humans, Prospective Studies, Stress, Mechanical, Tibia, Tibial Fractures, Time Factors, External Fixators, Weight-Bearing, Fracture Healing
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.