Tibial Nonunion Treated With Direct Current, Capacitive Coupling, or Bone Graft
The DOI matches its Crossref record.
Abstract
Two hundred seventy-one tibial nonunions of average duration of 23.5 months (range, 9-69 months) were treated with direct current (167 patients), capacitive coupled electrical stimulation (56 patients), or bone graft surgery (48 patients). Logistic regression analysis was used to compare heal rates among the 3 treatment methods, to identify risk factors adversely affecting the heal rate, and to predict the probability of successful healing of a nonunion of any given risk profile treated with each of the 3 forms of therapy. Seven risk factors were identified: duration of nonunion, prior bone graft surgery, prior electrical treatment, open fracture, osteomyelitis, comminuted or oblique fracture, and atrophic nonunion. When no risk factors were present, there were no significant differences among the 3 treatment methods. As progressively more risk factors were present, the predicted heal rates decreased significantly regardless of the treatment method. Some differences among the treatment groups did appear in the heal rates: bone graft surgery yielded a worse heal rate when there was a previous bone graft failure, and capacitive coupling had a worse heal rate in the presence of an atrophic nonunion.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Clinical studies on the effect of CC on long-bone nonunions have been published, but to date (68, 69), to the author’s knowledge, no study on CC has focused on fracture-healing speed or acceleration in long-bone fractures.”
From Methods to accelerate fracture healing – a narrative review from a clinical perspective (2024) · cites this paper as [69]
Citations
Cites
Still being checked.
Cited by
Items 101–116 of 116
A Personal Remembrance of Carl T. Brighton MD, PhD (1931-2019)
Green, S. A. (2020) · Clinical Orthopaedics and Related Research · doi:10.1097/corr.0000000000001166 · Cited by 1
Design considerations for piezocomposite materials for electrical stimulation in medical implants
Krech, E. D., Haas, E. G., Tideman, G., Reinsch, B., & Friis, E. A. (2022) · Journal of Medical Engineering & Technology · doi:10.1080/03091902.2022.2080881 · Cited by 1
Mechanical Stress for the Bone and Soft Tissues
Ito, H. (2002) · Journal of Nippon Medical School · doi:10.1272/jnms.69.146 · Cited by 1
Microcurrent therapy in the management of chronic tennis elbow
Poltawski, L. (2011) · University of Hertfordshire Research Archive (University of Hertfordshire) · Cited by 1
Castro, J. A. E., Hernández, A. G., Valero, A. L., Francisco Romo, C., & Trujano, A. G. (2002) · Acta Ortopédica Mexicana
THE USE OF METALS IN TRAUMATOLOGY AND ORTHOPEDICS: HISTORY OF PROBLEM
Владимирович, У. И., Николаевна, Л. С., Борисович, Н. С., & Георгиевич, П. Б. (2013) · Сибирский медицинский журнал (Иркутск)
Electromagnetismo: aplicaciones clínicas en aparato musculoesquelético
Borrego, P. D., Torrico, J. M. F., & Castilla, J. P. (2003) · Rehabilitación · doi:10.1016/s0048-7120(03)73358-1
Al-Zu’be, L. A., AlMomani, T., Altrabsheh, B., & Al-Zoubi, M. Z. (2013) · Jordan Journal of Biological Sciences · doi:10.12816/0000275
The associations between variables in large databases
Peterson, M. G. E., & Lane, J. M. (2003) · Proceedings - IEEE Symposium on Computer-Based Medical Systems · doi:10.1109/cbms.2003.1212763
Estudo do efeito de campo elétrico pulsado no reparo ósseo em tíbia de ratos
Calixto, S. P. (2007) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/d.82.2007.tde-28052008-104224
The Management of Carpal Scaphoid Fractures and Nonunions and the Role of Capacitive Systems
Borelli, P. P. (2018) · Springer eBooks · doi:10.1007/978-3-319-52902-8_15
Mosheiff, R., & Leung, F. K. L. (2014) · Springer eBooks · doi:10.1007/978-1-4471-6612-2_22
Noninvasive Technologies for Fracture Repair
Watanabe, Y., Kobayashi, M., & Matsushita, T. (2011) · Wiley eBooks · doi:10.1002/9781444345100.ch72
Nanni, M. (2014) · AMS Dottorato Institutional Doctoral Theses Repository (University of Bologna) · doi:10.6092/unibo/amsdottorato/6229
Frost (2004) · doi:10.1043/0003-3219(2004)074<0003:auobpa>2.0.co;2
Metadata
- Authors
- Brighton, C. T., Shaman, P., Bruce, R., Esterhai, J. L., Pollack, S. R., & Friedenberg, Z. B.
- Affiliations
- Division of Mathematical Sciences (US)
- University of Pennsylvania (US)
- Corresponding author
- Brighton, Carl T.
- Shaman, Paul
- Esterhai, John L.
- Friedenberg, Z. B.
- Venue
- Clinical Orthopaedics and Related Research
- Published
- 1995-12
- Volume
- 321
- Issue
- 321
- Pages
- 223-234
- ISSN
- 0009-921X (ISSN-L)
- OpenAlex
- W1995949046
- Semantic Scholar
- c6fbff0841e227c12696b1dd5cfb0484b87c9b57
- Cited by
- 116
- References
- 0
- Citations by year
- 2026: 2 · 2024: 1 · 2023: 1 · 2022: 2 · 2020: 2 · 2019: 1 · 2018: 3 · 2017: 3 · 2016: 2 · 2015: 5 · 2014: 8 · 2013: 8 · 2012: 6
- FWCI
- 1.38
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Clinical Orthopaedics and Related Research (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institute of Arthritis and Musculoskeletal and Skin Diseases (AR18033)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone fractures and treatments
- Health Sciences › Medicine › Surgery › Spinal Fractures and Fixation Techniques
- Health Sciences › Medicine › Surgery › Hip and Femur Fractures
- Keywords
- tibial nonunion, electrical stimulation, direct current, capacitive coupling, bone grafting, fracture healing, risk factors, atrophic nonunion, osteomyelitis, open fractures, comminuted fractures
- MeSH terms
- Adult, Electric Stimulation Therapy, Female, Fractures, Ununited, Humans, Male, Risk Factors, Tibial Fractures, Time Factors, Transplantation, Autologous, Logistic Models, Bone Transplantation, Fracture Healing, Treatment Failure
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.