The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Particulate Bioglass Compared With Hydroxyapatite as a Bone Graft Substitute
Abstract
Bioactive ceramics, notably hydroxyapatite, have been used clinically in various situations in which bone augmentation and restoration are required. Particulate material has been used either alone or in conjunction with freeze dried or autologous bone, with variable clinical success. In this study a bioactive glass, 45S5 Bioglass, has been compared with hydroxyapatite in an animal model to discover whether the 2 major disadvantages of hydroxyapatite may be overcome. These are the difficulty of placing and retaining the particulate in the defect and the length of time needed before full bony restoration is achieved. Bioglass is shown to be easy to manipulate and hemostatic and allows full restoration of bone in 2 weeks, rather than the 12 weeks needed for the particulate hydroxyapatite to produce a comparable response. The Bioglass particulate is used up in the process, and any problems that may be associated with the production of a composite of bone and biomaterial are avoided in the fully restored bone. In any procedure that requires bony augmentation, this rapid response to Bioglass is expected to provide a clinical advantage.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bioceramics: From Concept to Clinic
Hench, L. L. (1991) · Journal of the American Ceramic Society · doi:10.1111/j.1151-2916.1991.tb07132.x · Cited by 4,977
Self-citationBone graft and bone graft substitutes: A review of current technology and applications
Damien, C. J., & Parsons, J. R. (1991) · Journal of Applied Biomaterials · doi:10.1002/jab.770020307 · Cited by 1,058
Orthopaedic applications of hydroxyapatite
Oonishi, H. (1991) · Biomaterials · doi:10.1016/0142-9612(91)90196-h · Cited by 280
Self-citationBioactive ceramics for periodontal treatment: Comparative studies in the patus monkey
Wilson, J., & Low, S. B. (1992) · Journal of Applied Biomaterials · doi:10.1002/jab.770030208 · Cited by 256
Self-citationKeeting, P. E., Oursler, M. J., Wiegand, K. E., Bonde, S. K., Spelsberg, T. C., & Riggs, B. L. (1992) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650071107 · Cited by 249
Cited by
Hench, L. L. (2006) · Journal of Materials Science: Materials in Medicine · doi:10.1007/s10856-006-0432-z · Cited by 2,505
Self-citationReview of bioactive glass: From Hench to hybrids
Jones, J. R. (2013) · Acta Biomaterialia · doi:10.1016/j.actbio.2012.08.023 · Cited by 2,451
45S5 Bioglass®-derived glass–ceramic scaffolds for bone tissue engineering
Chen, Q. Z., Thompson, I. D., & Boccaccini, A. R. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.11.025 · Cited by 1,241
Xynos, I. D., Edgar, A. J., Buttery, L. D. K., Hench, L. L., & Polak, J. M. (2000) · Biochemical and Biophysical Research Communications · doi:10.1006/bbrc.2000.3503 · Cited by 983
Self-citationBioceramics: Past, present and for the future
Best, S. M., Porter, A. E., Thian, E. S., & Huang, J. (2008) · Journal of the European Ceramic Society · doi:10.1016/j.jeurceramsoc.2007.12.001 · Cited by 851
Metadata
- Authors
- OONISHI, H., KUSHITANI, S., YASUKAWA, E., IWAKI, H., HENCH, L. L., WILSON, J., TSUJI, E., & SUGIHARA, T.
- Venue
- Clinical Orthopaedics and Related Research
- Published
- 1997-01
- Volume
- 334
- Issue
- 334
- Pages
- 316???325
- ISSN
- 0009-921X (ISSN-L)
- OpenAlex
- W2087111940
- Cited by
- 290
- References
- 5
- FWCI
- 8.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Particulate Bioglass Compared With Hydroxyapatite as a Bone Graft Substitute. https://app.cochat.ai/papers/10.1097/00003086-199701000-00041
- The paper
- OONISHI, H., KUSHITANI, S., YASUKAWA, E., IWAKI, H., HENCH, L. L., WILSON, J., TSUJI, E., & SUGIHARA, T. (1997). Particulate Bioglass Compared With Hydroxyapatite as a Bone Graft Substitute. Clinical Orthopaedics and Related Research. https://doi.org/10.1097/00003086-199701000-00041
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.