A Fully Implantable Motorized Intramedullary Nail for Limb Lengthening and Bone Transport
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
This article describes an intramedullary nail that contains a fully implantable motorized programmable sliding mechanism for limb lengthening and bone transport that reduces the risk of infection, discomfort, and scarring usually associated with the external fixators used for the same purpose. Twelve patients were treated surgically with the new system. Eleven patients had unilateral femur shortening between 3 and 7.5 cm, and one patient had a 12-cm defect after tumor resection. In all patients with femur shortening the leg length discrepancy was corrected completely. In the case of bone defect the segment transport worked well without any problems. There was no infection and no axial deformity. Immediately after chemotherapy, delayed bone formation was seen. In two early cases of limb lengthening a technical problem led to replacement of the motor.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Problems, Obstacles, and Complications of Limb Lengthening by the Ilizarov Technique
PALEY, D. (1990) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199001000-00011 · Cited by 1,499
Clinical Application of the Tension-Stress Effect for Limb Lengthening
ILIZAROV, G. A. (1990) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199001000-00003 · Cited by 1,217
Current Techniques of Limb Lengthening
Paley, D. (1988) · Journal of Pediatric Orthopaedics · doi:10.1097/01241398-198801000-00018 · Cited by 395
Bone lengthening in rabbits by callus distraction. The role of periosteum and endosteum
Kojimoto, H., Yasui, N., Goto, T., Matsuda, S., & Shimomura, Y. (1988) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.70b4.3403595 · Cited by 382
Cited by
Cole, J. D., Justin, D., Kasparis, T., DeVlught, D., & Knobloch, C. (2001) · Injury · doi:10.1016/s0020-1383(01)00116-4 · Cited by 210
“[20] further reported 12 additional successful femoral lengthening cases with a similar device.”
BackgroundPRECICE intramedullary limb lengthening system
Paley, D. (2015) · Expert Review of Medical Devices · doi:10.1586/17434440.2015.1005604 · Cited by 200
“Baumgart’s cohort of 12 patients attained complete length objectives in all patients [2].”
BackgroundGlatt, V., Evans, C. H., & Tetsworth, K. (2017) · Frontiers in Physiology · doi:10.3389/fphys.2016.00678 · Cited by 194
“…nail. various implants available use different strategies to provide the necessary distraction force, including mechanical, motorized, or magnetic devices (Betz et al., 1990; Baumgart et al., 1997; Cole et al., 2001; Thaller et al., 2014; Kucukkaya et al., 2015; Paley, 2015; Paley et al., 2015).”
MethodCurrent management of long bone large segmental defects
Lasanianos, N. G., Kanakaris, N. K., & Giannoudis, P. V. (2010) · Orthopaedics and Trauma · doi:10.1016/j.mporth.2009.10.003 · Cited by 167
Metadata
- Authors
- Baumgart, R., Betz, A., & Schweiberer, L.
- Venue
- Clinical Orthopaedics and Related Research
- Published
- 1997-10
- Volume
- 343
- Issue
- 343
- Pages
- 135???143
- ISSN
- 0009-921X (ISSN-L)
- OpenAlex
- W1965345896
- Cited by
- 227
- References
- 4
- FWCI
- 1.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.