CoChat

Functional Medial Ligament Balancing in Total Knee Arthroplasty

Whiteside, Leo A., Saeki, Kazuhiko, Mihalko, William M. · 2000 · Clinical Orthopaedics and Related Research
Cited by 186

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

Function of the anterior and posterior oblique portions of the medial collateral ligament and the posterior capsule in flexion and extension was evaluated in eight knee specimens after posterior cruciate retaining total knee arthroplasty. The posterior oblique portion of the medial collateral ligament was released subperiosteally in four specimens, and the anterior portion was released in four specimens. The medial posterior capsule was released in each group, then the remaining portion of the medial collateral ligament was released. Release of the posterior oblique portion produced moderate laxity at full extension and at 30 degrees flexion, and posterior capsule release produced additional laxity in full extension. Release of the anterior portion produced major laxity at 60 degrees and 90 degrees flexion. Complete medial collateral ligament release increased laxity significantly in both groups in flexion and extension. This rationale was tested in a clinical study of 82 knees (76 patients) in which 62 (76%) required medial collateral ligament release to correct varus deformity during posterior cruciate retaining total knee arthroplasty. Twenty-two knees (35.5%) were tight medially in extension only, and were corrected by releasing the posterior oblique portion. Thirty-one knees (50%) were tight medially in flexion only, and were corrected by releasing the anterior portion. Nine knees (14.5%) were tight medially in flexion and extension and required complete medial collateral ligament release, but three knees (4.8%) remained tight in extension and required medial posterior capsule release to correct flexion contracture and medial ligament contracture. Seventeen (27%) had partial posterior cruciate ligament release to correct excessive rollback of the femoral component on the tibial surface.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00003086-200011000-00007

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Metadata

Authors
Whiteside, L. A., Saeki, K., & Mihalko, W. M.
Venue
Clinical Orthopaedics and Related Research
Published
2000-11
Volume
380
Issue
380
Pages
45-57
ISSN
0009-921X (ISSN-L)
OpenAlex
W1994493868
Cited by
186
References
10
FWCI
3.41
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Functional Medial Ligament Balancing in Total Knee Arthroplasty. https://app.cochat.ai/papers/10.1097/00003086-200011000-00007
The paper
Whiteside, L. A., Saeki, K., & Mihalko, W. M. (2000). Functional Medial Ligament Balancing in Total Knee Arthroplasty. Clinical Orthopaedics and Related Research. https://doi.org/10.1097/00003086-200011000-00007

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.