Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 474

The DOI matches its Crossref record.

Wear Is a Function of Use, Not Time

Schmalzried, Thomas P., Shepherd, Eric F., Dorey, Frederick J., Jackson, Walter O., dela Rosa, Mylene, Fa???vae, Fa???vae, McKellop, Harry A., McClung, Christian D., Martell, John, Moreland, John R., Amstutz, Harlan C.·2000·Clinical Orthopaedics and Related Research

Abstract

Polyethylene wear (linear penetration) in 37 hip replacements was assessed from digital images using a validated two-dimensional, edge detection-based computer algorithm. Patient activity was assessed with a pedometer, a step activity monitor and a simple visual analog scale. Joint use was related to wear at the 90% confidence level. Without three recognized outliers, wear was highly correlated to use. The visual analog scale activity rating was significantly related to wear for the 24 hip replacements with standard polyethylene. Univariate regression analysis indicated that male gender, height, weight (which were both highly correlated to male gender) and hip center of rotation were significantly correlated to wear. Multivariate regression analysis indicated that male gender, femoral off-set, and Hylamer were significantly correlated to wear. Based on the wear and activity data from the 24 hip replacements with standard polyethylene, the average volumetric wear rate per million cycles with a 70 kg patient weight was 30 mm3. This unique in vivo result can be considered a target wear rate for standard polyethylene in hip simulator studies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00003086-200012000-00005

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 474

Metadata

Authors
Schmalzried, T. P., Shepherd, E. F., Dorey, F. J., Jackson, W. O., dela Rosa, M., Fa???vae, F., McKellop, H. A., McClung, C. D., Martell, J., Moreland, J. R., & Amstutz, H. C.
Venue
Clinical Orthopaedics and Related Research
Published
2000-12
Volume
381
Issue
381
Pages
36-46
ISSN
0009-921X (ISSN-L)
OpenAlex
W2047412384
Cited by
474
References
0
FWCI
8.54
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Wear Is a Function of Use, Not Time. https://app.cochat.ai/papers/10.1097/00003086-200012000-00005
The paper
Schmalzried, T. P., Shepherd, E. F., Dorey, F. J., Jackson, W. O., dela Rosa, M., Fa???vae, F., McKellop, H. A., McClung, C. D., Martell, J., Moreland, J. R., & Amstutz, H. C. (2000). Wear Is a Function of Use, Not Time. Clinical Orthopaedics and Related Research. https://doi.org/10.1097/00003086-200012000-00005

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.