High-Energy Extracorporeal Shock Wave Treatment of Nonunions
The DOI matches its Crossref record.
Abstract
Forty-three consecutive patients who did not have healing of tibial or femoral diaphyseal and metaphyseal fractures and osteotomies for at least 9 months after injury or surgery were examined prospectively for use of high-energy extracorporeal shock waves. Former treatment modalities (cast, external fixator, plate osteosynthesis, limitation of weightbearing) remained unchanged. In all cases a 99mTechnetium dicarboxyphosphonate regional two-phase bone scintigraphy was performed before one treatment with 3,000 impulses of an energy flux density of 0.6 mJ/mm2. Radiologic and clinical followups were done at 4-week intervals starting 8 weeks after shock wave treatment. The success criterion was bridging of all four cortices in the anteroposterior and lateral radiographic views, in oblique views, or by conventional tomography. An independent observer described bony consolidation in 31 of 43 cases (72%) after an average of 4 months (range, 2-7 months). Twenty-nine of 35 (82.9%) patients with a positive bone scan had healing of the pseudarthrosis compared with two of eight (25%) patients with a negative bone scan. Six of these eight patients with negative scans were heavy smokers. No complications were observed. High-energy shock wave therapy seemed to be an effective noninvasive tool for stimulation of bone healing in properly selected patients with a diaphyseal or metaphyseal nonunion of the femur or tibia. Additional controlled studies are mandatory.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Therapeutic applications of ultrasound
ter Haar, G. (2007) · Progress in Biophysics and Molecular Biology · doi:10.1016/j.pbiomolbio.2006.07.005 · Cited by 721
Shock wave therapy induces neovascularization at the tendon–bone junction. A study in rabbits
Wang, C., Wang, F., Yang, K. D., Weng, L., Hsu, C., Huang, C., & Yang, L. (2003) · Journal of Orthopaedic Research · doi:10.1016/s0736-0266(03)00104-9 · Cited by 629
Extracorporeal shockwave therapy in musculoskeletal disorders
Wang, C.-J. (2012) · Journal of Orthopaedic Surgery and Research · doi:10.1186/1749-799x-7-11 · Cited by 527
Molecular and Antibiofilm Approaches to Prosthetic Joint Infection
Trampuz, A., Osmon, D. R., Hanssen, A. D., Steckelberg, J. M., & Patel, R. (2003) · Clinical Orthopaedics and Related Research · doi:10.1097/01.blo.0000087324.60612.93 · Cited by 293
The health economics of the treatment of long-bone non-unions
Kanakaris, N. K., & Giannoudis, P. V. (2007) · Injury · doi:10.1016/s0020-1383(07)80012-x · Cited by 256
Metadata
- Authors
- Rompe, J. D., Rosendahl, T., Sch??llner, C., & Theis, C.
- Venue
- Clinical Orthopaedics and Related Research
- Published
- 2001-06
- Volume
- 387
- Issue
- 387
- Pages
- 102-111
- ISSN
- 0009-921X (ISSN-L)
- OpenAlex
- W2078207021
- Cited by
- 144
- References
- 0
- FWCI
- 6.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High-Energy Extracorporeal Shock Wave Treatment of Nonunions. https://app.cochat.ai/papers/10.1097/00003086-200106000-00014
- The paper
- Rompe, J. D., Rosendahl, T., Sch??llner, C., & Theis, C. (2001). High-Energy Extracorporeal Shock Wave Treatment of Nonunions. Clinical Orthopaedics and Related Research. https://doi.org/10.1097/00003086-200106000-00014
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.