CoChat

Strain in the Human Medial Collateral Ligament During Valgus Loading of the Knee

Gardiner, John C., Weiss, Jeffrey A., Rosenberg, Thomas D. · 2001 · Clinical Orthopaedics and Related Research
Cited by 167

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

Abstract

The medial collateral ligament is one of the most frequently injured ligaments in the knee. Although the medial collateral ligament is known to provide a primary restraint to valgus and external rotations, details regarding its precise mechanical function are unknown. In this study, strain in the medial collateral ligament of eight knees from male cadavers was measured during valgus loading. A material testing machine was used to apply 10 cycles of varus and valgus rotation to limits of +/- 10.0 N-m at flexion angles of 0 degrees, 30 degrees, 60 degrees, and 90 degrees. A three-dimensional motion analysis system measured local tissue strain on the medial collateral ligament surface within 12 regions encompassing nearly the entire medial collateral ligament surface. Results indicated that strain is significantly different in different regions over the surface of the medial collateral ligament and that this distribution of strain changes with flexion angle and with the application of a valgus torque. Strain in the posterior and central portions of the medial collateral ligament generally decreased with increasing flexion angle, whereas strain in the anterior fibers remained relatively constant with changes in flexion angle. The highest strains in the medial collateral ligament were found at full extension on the posterior side of the medial collateral ligament near the femoral insertion. These data support clinical findings that suggest the femoral insertion is the most common location for medial collateral ligament injuries.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00003086-200110000-00031

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 13 references

Research works printed but not linked: 8

  1. Gardiner, 1998, Trans Orthop Res Soc, 23, 1027
  2. Miyasaka, 1991, Am J Knee Surg, 4, 3
  3. Sakane, 1999, Knee Surg Sports Traumatol Arthrosc, 7, 93, 10.1007/s001670050128 · doi:10.1007/s001670050128
  4. Shapiro, 1991, J Bone Joint Surg, 73A, 248, 10.2106/00004623-199173020-00013 · doi:10.2106/00004623-199173020-00013
  5. Shapiro, 1978, Res Q, 49, 197
  6. To, 1988, J Biomech, 21, 511, 10.1016/0021-9290(88)90243-6 · doi:10.1016/0021-9290(88)90243-6
  7. Weiss, 1995, Proc ASME Bioeng Con, 29, 105
  8. Woo, 1990, J Biomech Eng, 111, 46, 10.1115/1.2891125 · doi:10.1115/1.2891125

Cited by

See all 167

Metadata

Authors
Gardiner, J. C., Weiss, J. A., & Rosenberg, T. D.
Venue
Clinical Orthopaedics and Related Research
Published
2001-10
Volume
391
Issue
391
Pages
266-274
ISSN
0009-921X (ISSN-L)
OpenAlex
W2086545874
Cited by
167
References
13
FWCI
2.17
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Strain in the Human Medial Collateral Ligament During Valgus Loading of the Knee. https://app.cochat.ai/papers/10.1097/00003086-200110000-00031
The paper
Gardiner, J. C., Weiss, J. A., & Rosenberg, T. D. (2001). Strain in the Human Medial Collateral Ligament During Valgus Loading of the Knee. Clinical Orthopaedics and Related Research. https://doi.org/10.1097/00003086-200110000-00031

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.