The DOI matches its Crossref record.
Continuous noninvasive real-time monitoring of stroke volume and cardiac output by thoracic electrical bioimpedance
Abstract
Thoracic electrical bioimpedance (TEB) is a noninvasive method for the estimation of left ventricular stroke volume (SV). Objections to TEB in the past have included systematic overestimation of SV and cardiac output in normals, poor correlation in absolute terms with standard cardiac output reference techniques, motion and ventilation artifacts which distorted recorded waveforms except when patients remained in apnea during measurements, and lack of a computer to yield rapid heat-to-beat quantitation of SV and cardiac output. The present study entails real-time, beat-to-beat cardiac output determinations using TEB and assessing its agreement via a digital computer against a reference standard, thermodilution. A correlation coefficient of 0.88 is reported with 85% of data points falling within 20% confidence limits on either side of the line of identity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Noninvasive cardiac output monitoring (NICOM): a clinical validation
Squara, P., Denjean, D., Estagnasie, P., Brusset, A., Dib, J. C., & Dubois, C. (2007) · Intensive Care Medicine · doi:10.1007/s00134-007-0640-0 · Cited by 320
Hypocapnia and Cerebral Hypoperfusion in Orthostatic Intolerance
Novak, V., Spies, J. M., Novak, P., McPhee, B. R., Rummans, T. A., & Low, P. A. (1998) · Stroke · doi:10.1161/01.str.29.9.1876 · Cited by 191
Low, P. A., Opfer-Gehrking, T. L., Textor, S. C., Schondorf, R., Suarez, G. A., Fealey, R. D., & Camilleri, M. (1994) · Journal of the Autonomic Nervous System · doi:10.1016/0165-1838(94)90008-6 · Cited by 105
Metadata
- Authors
- BERNSTEIN, D. P.
- Venue
- Critical Care Medicine
- Published
- 1986-10
- Volume
- 14
- Issue
- 10
- Pages
- 898-901
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W2049082621
- Cited by
- 212
- References
- 0
- FWCI
- 11.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Continuous noninvasive real-time monitoring of stroke volume and cardiac output by thoracic electrical bioimpedance. https://app.cochat.ai/papers/10.1097/00003246-198610000-00015
- The paper
- BERNSTEIN, D. P. (1986). Continuous noninvasive real-time monitoring of stroke volume and cardiac output by thoracic electrical bioimpedance. Critical Care Medicine. https://doi.org/10.1097/00003246-198610000-00015
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.