A simple technique to accurately determine intra-abdominal pressure
Abstract
The determination of intra-abdominal pressure (IAP) may be useful in a variety of clinical situations. Despite this, invasive IAP monitoring is seldom performed due to the risks involved. Using a standard canine model of increased IAP, we evaluated the accuracy of transurethral bladder catheter pressure in reflecting IAP. Throughout the range of IAP studied (10 +/- 5 to 70 +/- 10 mm Hg), bladder pressure did not differ significantly from the direct measurement of IAP. We conclude that the measurement of bladder pressure using a standard transurethral bladder catheter provides an accurate determination of IAP.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
THE ABDOMINAL COMPARTMENT SYNDROME
Burch, J. M., Moore, E. E., Moore, F. A., & Franciose, R. (1996) · Surgical Clinics of North America · doi:10.1016/s0039-6109(05)70483-7 · Cited by 548
Different techniques to measure intra-abdominal pressure (IAP): time for a critical re-appraisal
Malbrain, M. L. N. G. (2004) · Intensive Care Medicine · doi:10.1007/s00134-003-2107-2 · Cited by 486
Normal Intraabdominal Pressure in Healthy Adults
Cobb, W. S., Burns, J. M., Kercher, K. W., Matthews, B. D., James Norton, H., & Todd Heniford, B. (2005) · Journal of Surgical Research · doi:10.1016/j.jss.2005.06.015 · Cited by 460
Prospective characterization and selective management of the abdominal compartment syndrome
Meldrum, D. R., Moore, F. A., Moore, E. E., Franciose, R. J., Sauaia, A., & Burch, J. M. (1997) · The American Journal of Surgery · doi:10.1016/s0002-9610(97)00201-8 · Cited by 443
THE DAMAGE CONTROL SEQUENCE AND UNDERLYING LOGIC
Rotondo, M. F., & Zonies, D. H. (1997) · Surgical Clinics of North America · doi:10.1016/s0039-6109(05)70582-x · Cited by 441
Metadata
- Authors
- IBERTI, T. J., KELLY, K. M., GENTILI, D. R., HIRSCH, S., & BENJAMIN, E.
- Venue
- Critical Care Medicine
- Published
- 1987-12
- Volume
- 15
- Issue
- 12
- Pages
- 1140-1142
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W1971124791
- Cited by
- 246
- References
- 0
- FWCI
- 1.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A simple technique to accurately determine intra-abdominal pressure. https://app.cochat.ai/papers/10.1097/00003246-198712000-00014
- The paper
- IBERTI, T. J., KELLY, K. M., GENTILI, D. R., HIRSCH, S., & BENJAMIN, E. (1987). A simple technique to accurately determine intra-abdominal pressure. Critical Care Medicine. https://doi.org/10.1097/00003246-198712000-00014
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.