OBJECTIVE: To compare three devices that measure core body temperature at the bedside in ICU patients. DESIGN: Prospective, consecutive sample. SETTING: Voluntary community teaching hospital. PATIENTS: Fifteen patients, 78 +/- 6 (SD) yrs of age, admitted to the medical ICU over a 5-month period who had pulmonary artery catheters inserted as part of their routine care were studied. Thirteen patients were studied once, one patient twice, and one patient six times for a total of 21 sets of measurements. INTERVENTIONS: All patients had urinary bladder thermistor catheters inserted just before pulmonary artery catheterization. Simultaneous core temperatures were measured for the duration of pulmonary artery catheterization every 4 hrs by the pulmonary artery thermistor catheter, the bladder thermistor catheter, and by a tympanic membrane infrared probe set on its core temperature setting. The three devices were then compared with each other in vitro using a specialized constant water bath setup. Finally, two of the tympanic membrane infrared probes were compared with each other in 20 ambulatory emergency department patients. MEASUREMENTS AND MAIN RESULTS: Over 32 hrs of pulmonary artery catheterization, the pulmonary artery thermistor catheters and bladder thermistor catheters showed excellent agreement, with a bias of only -0.04 degrees C between the two. However, the bias comparing the tympanic membrane infrared probe with the pulmonary artery thermistor catheter was -0.38 degrees C, and the bias was -0.34 degrees C comparing the tympanic membrane infrared probe with the bladder thermistor catheter. The tympanic membrane infrared probe readings remained significantly higher than the pulmonary artery thermistor catheter or bladder thermistor catheter readings over the entire 32-hr period. The two tympanic membrane infrared probes compared with each other in emergency room patients showed excellent agreement (p less than .001). In the in vivo water bath setup, the tympanic membrane infrared probe on most of its settings again registered significantly (p less than .01) higher than both the pulmonary artery thermistor catheter and the bladder thermistor catheter. CONCLUSIONS: Pulmonary artery thermistor catheters and bladder thermistor catheters appear to give consistent, highly reliable bedside measurements of core body temperature in ICU patients. The currently available device that measures core body temperature from the tympanic membrane appears to give erroneously high readings, and should be used with caution.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00003246-199106000-00015

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 96

Metadata

Authors
NIERMAN, D. M.
Venue
Critical Care Medicine
Published
1991-06
Volume
19
Issue
6
Pages
818-823
ISSN
0090-3493 (ISSN-L)
OpenAlex
W2008079891
Cited by
96
References
0
FWCI
2.76
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Core temperature measurement in the intensive care unit. https://app.cochat.ai/papers/10.1097/00003246-199106000-00015
The paper
NIERMAN, D. M. (1991). Core temperature measurement in the intensive care unit. Critical Care Medicine. https://doi.org/10.1097/00003246-199106000-00015

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.