Effect of extracorporeal membrane oxygenation on platelets in newborns
The DOI matches its Crossref record.
Abstract
OBJECTIVES: To examine the effect of extracorporeal membrane oxygenation (ECMO) therapy on platelet function and number and to determine the in vivo survival of transfused platelets during ECMO. DESIGN: Prospective study of all neonates treated with ECMO during a 6-month period. SETTING: Neonatal intensive care unit in a tertiary referral center. PATIENTS: Ten infants, < 1 wk of age, with respiratory failure requiring ECMO. INTERVENTIONS: None. MEASUREMENTS: Platelet counts were measured at timed intervals to determine the effect of ECMO on platelet counts. The change in platelet counts after transfusion was also measured. Whole blood platelet aggregation studies were performed to determine the effect of ECMO on platelet function. MAIN RESULTS: A mean decrease of 26% from the baseline platelet count was found 15 mins after the initiation of ECMO, with an additional mean decrease of 16% by the end of 1 hr (p < .05). Fifteen minutes after platelet transfusions, a 17% mean increase in platelet counts was measured (p < .05). One hour after platelet transfusion, the platelet count had decreased to pretransfusion values. Platelet aggregation studies 15 mins after starting ECMO showed a 46% mean decrease in the response to collagen from baseline (p > .05), and a significantly (p < .05) reduced response to ristocetin and to adenosine 5'-diphosphate. Platelet adenosine triphosphate release was also significantly reduced. Single-unit platelet transfusions failed to correct platelet aggregation abnormalities. Resolution of platelet aggregation abnormalities and normalization of platelet counts occurred 8 hrs off ECMO. CONCLUSIONS: The results of these studies show that qualitative and quantitative platelet changes occur while a neonate is receiving ECMO. The survival rate of transfused platelets is reduced, and the acquired platelet dysfunction is not reversed by the transfusion of platelets with normal function while the patient is receiving ECMO.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ferraris, V. A., Brown, J. R., Despotis, G. J., Hammon, J. W., Reece, T. B., Saha, S. P., Song, H. K., Clough, E. R., Shore-Lesserson, L. J., Goodnough, L. T., et al. (2011) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2010.11.078 · Cited by 1,289
Esper, S. A., Levy, J. H., Waters, J. H., & Welsby, I. J. (2014) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000000115 · Cited by 195
Obi, A. T., Tignanelli, C. J., Jacobs, B. N., Arya, S., Park, P. K., Wakefield, T. W., Henke, P. K., & Napolitano, L. M. (2019) · Journal of Vascular Surgery: Venous and Lymphatic Disorders · doi:10.1016/j.jvsv.2018.08.010 · Cited by 166
Wo, Y., Li, Z., Brisbois, E. J., Colletta, A., Wu, J., Major, T. C., Xi, C., Bartlett, R. H., Matzger, A. J., & Meyerhoff, M. E. (2015) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.5b07501 · Cited by 128
Brisbois, E. J., Davis, R. P., Jones, A. M., Major, T. C., Bartlett, R. H., Meyerhoff, M. E., & Handa, H. (2015) · Journal of Materials Chemistry B · doi:10.1039/c4tb01839g · Cited by 101
Metadata
- Authors
- ROBINSON, T. M., KICKLER, T. S., WALKER, L. K., NESS, P., & BELL, W.
- Venue
- Critical Care Medicine
- Published
- 1993-07
- Volume
- 21
- Issue
- 7
- Pages
- 1029-1034
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W2012568287
- Cited by
- 109
- References
- 0
- FWCI
- 1.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effect of extracorporeal membrane oxygenation on platelets in newborns. https://app.cochat.ai/papers/10.1097/00003246-199307000-00018
- The paper
- ROBINSON, T. M., KICKLER, T. S., WALKER, L. K., NESS, P., & BELL, W. (1993). Effect of extracorporeal membrane oxygenation on platelets in newborns. Critical Care Medicine. https://doi.org/10.1097/00003246-199307000-00018
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.