The DOI matches its Crossref record.
A prospective, randomized trial of gauze and two polyurethane dressings for site care of pulmonary artery catheters: Implications for catheter management
Abstract
OBJECTIVES: To compare the safety of a conventional polyurethane transparent dressing and a novel highly permeable polyurethane dressing, as compared with standard gauze and tape, as site dressings for pulmonary artery catheters; and to rigorously determine the sources of bloodstream infections deriving from these catheters. DESIGN: Prospective, randomized, clinical trial. SETTING: General adult intensive care units (ICUs) in a university hospital. PATIENTS: A total of 442 adult patients with pulmonary artery catheters were studied. Two thirds of the catheters had been inserted in the operating room and one third had been inserted in an ICU. INTERVENTIONS: Patients were randomized at the time of pulmonary artery catheter insertion to have one of three dressing regimens: a) sterile gauze and tape (control), replaced every 2 days; b) a conventional polyurethane dressing, replaced every 5 days; or c) a highly permeable polyurethane dressing, also replaced every 5 days. MEASUREMENTS AND MAIN RESULTS: The origin of each catheter-associated bloodstream infection was sought by quantitatively culturing the skin of the insertion site and all potential sources on the catheter, including the hub and infusate from each lumen of the introducer sheath and the pulmonary artery catheter, and intravascular segments of the introducer sheath and pulmonary artery catheter. Bloodstream infection was confirmed by demonstrating concordance between isolates from the device and blood cultures by pulsed-field electrophoresis of genomic DNA, digested with low-frequency-cleavage, restriction endonucleases. One hundred thirty catheters were randomized to be dressed with sterile gauze and tape (control), 127 with the conventional polyurethane dressing, and 185 with the highly permeable polyurethane dressing. Patients and catheters in the three dressing groups were very comparable. Ninety-six (21.7%) of the 442 catheters studied showed colonization of the introducer sheath or the pulmonary artery catheter, and five (1.1%) catheters caused bloodstream infection. Catheter-related bloodstream infections were associated with concordant cutaneous colonization of the insertion site (n = 2), a contaminated catheter hub or infusate (n = 3), contamination of the extravascular segment of a repositioned catheter beneath the external protective plastic sleeve (n = 1), or hematogenous colonization of the catheter (n = 1). All pulmonary artery catheter-related bloodstream infections occurred with catheters (introducers) in place for > or = 5 days (p < .001). Cutaneous colonization under the dressing at catheter removal was lowest with gauze (10(1.3) colony-forming units), intermediate with the new highly permeable polyurethane dressing (10(1.8) colony-forming units; p < .01), and highest with the conventional polyurethane dressing (10(2.0) colony-forming units; p < .001). There were no significant differences in catheter colonization (20.0 to 25.2 cases per 100 catheters) or catheter-related bloodstream infection (0.8 to 1.6 cases per 100 catheters) between the three groups. CONCLUSIONS: The incidence of pulmonary artery catheter-related bloodstream infection has decreased over the past 5 yrs. Pulmonary artery catheter-related bloodstream infections originate from multiple sources, indicating that measures to prevent bacteremic infections of these devices must focus both on reducing cutaneous colonization at the insertion site and averting contamination of infusate and catheter hubs. Efforts should be made to limit the duration of catheterization with pulmonary artery catheters (including the introducer) to no longer than 4 days. The polyurethane dressings studied appear to be safe for use with pulmonary artery catheters and may be left on for up to 5 days between dressing changes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Guidelines for the Prevention of Intravascular Catheter-related Infections
O'Grady, N. P., Alexander, M., Burns, L. A., Dellinger, E. P., Garland, J., Heard, S. O., Lipsett, P. A., Masur, H., Mermel, L. A., Pearson, M. L., et al. (2011) · Clinical Infectious Diseases · doi:10.1093/cid/cir257 · Cited by 4,699
Self-citationKDOQI Clinical Practice Guideline for Vascular Access: 2019 Update
Lok, C. E., Huber, T. S., Lee, T., Shenoy, S., Yevzlin, A. S., Abreo, K., Allon, M., Asif, A., Astor, B. C., Glickman, M. H., et al. (2020) · American Journal of Kidney Diseases · doi:10.1053/j.ajkd.2019.12.001 · Cited by 2,590
Preventing Complications of Central Venous Catheterization
McGee, D. C., & Gould, M. K. (2003) · New England Journal of Medicine · doi:10.1056/nejmra011883 · Cited by 2,290
Maki, D. G., Kluger, D. M., & Crnich, C. J. (2006) · Mayo Clinic Proceedings · doi:10.4065/81.9.1159 · Cited by 1,549
Self-citationESPGHAN and ESPEN Guidelines Paediatric Parenteral Nutrition ‐ Annex: List of Products
(2005) · Journal of Pediatric Gastroenterology and Nutrition · doi:10.1097/01.mpg.0000181841.07090.f4 · Cited by 1,231
Metadata
- Authors
- Maki, D. G., Stolz, S. S., Wheeler, S., & Mermel, L. A.
- Venue
- Critical Care Medicine
- Published
- 1994-11
- Volume
- 22
- Issue
- 11
- Pages
- 1729-1737
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W4235056984
- Cited by
- 177
- References
- 0
- FWCI
- 11.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A prospective, randomized trial of gauze and two polyurethane dressings for site care of pulmonary artery catheters: Implications for catheter management. https://app.cochat.ai/papers/10.1097/00003246-199411000-00006
- The paper
- Maki, D. G., Stolz, S. S., Wheeler, S., & Mermel, L. A. (1994). A prospective, randomized trial of gauze and two polyurethane dressings for site care of pulmonary artery catheters: Implications for catheter management. Critical Care Medicine. https://doi.org/10.1097/00003246-199411000-00006
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.