CoChat

Initial experience with partial liquid ventilation in pediatric patients with the acute respiratory distress syndrome

Gauger, Paul G, Pranikoff, Thomas, Schreiner, Robert J, Moler, Frank W, Hirschl, Ronald B · 1996 · Critical Care Medicine
Cited by 175

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: Liquid ventilation with perfluorocarbon previously has not been reported in pediatric patients with respiratory failure beyond the neonatal period. We evaluated the technique of partial liquid ventilation in six pediatric patients with the acute respiratory distress syndrome of sufficient severity to require extracorporeal life support (ECLS). DESIGN: This study was a noncontrolled, phase I/II experimental study with a single group pretest/posttest design. SETTING: All studies were performed at a tertiary, pediatric referral hospital at the University of Michigan Medical School. PATIENTS: Six pediatric patients, from 8 wks to 5 1/2 yrs of age, with severe respiratory failure requiring ECLS to support gas exchange. INTERVENTIONS: After 2 to 9 days on ECLS, perfluorocarbon was administered into the trachea until the dependent zone of each lung was filled. The initial administered was 12.9 +/- 2.3 mL/kg (range 5 to 20). Gas ventilation of the perfluorocarbon-filled lungs (partial liquid ventilation) was then performed. The perfluorocarbon dose was repeated daily for a total of 3 to 7 days, with a cumulative dose of 45.2 +/- 6.1 mL/kg (range 30 to 72.5). MEASUREMENTS AND MAIN RESULTS: All measurements of native gas exchange were made during brief periods of discontinuation of ECLS and include PaO2 and the alveolar-arterial oxygen gradient, P(A-a)O2. Static pulmonary compliance, corrected for weight, was also measured directly. The mean PaO2 increased from 39 +/- 6 to 92 +/- 29 torr (5.2 +/- 0.8 to 12.2 +/- 3.9 kPa) over the 96 hrs after the initial dose (p = .021 by repeated-measures analysis of variance). The average P(A-a)O2 decreased from 635 +/- 10 to 499 +/- 77 torr (84.7 +/- 1.3 to 66.5 +/- 10.3 kPa) over the same time period (p = .059), while the mean static pulmonary compliance (normalized for patient weight) increased from 0.12 +/- 0.02 to 0.28 +/- 0.08 mL/cm H2O/kg (p = .01). All six patients survived. Complications potentially associated with partial liquid ventilation were limited to pneumothoraces in two of six patients. CONCLUSIONS: Perfluorocarbon may be safely administered into the lungs of pediatric patients with severe respiratory failure on ECLS and may be associated with improvement in gas exchange and pulmonary compliance.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00003246-199601000-00006

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 175

Metadata

Authors
Gauger, P. G., Pranikoff, T., Schreiner, R. J., Moler, F. W., & Hirschl, R. B.
Venue
Critical Care Medicine
Published
1996-01
Volume
24
Issue
1
Pages
16-22
ISSN
0090-3493 (ISSN-L)
OpenAlex
W2006356492
Cited by
175
References
1
FWCI
28.39
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Initial experience with partial liquid ventilation in pediatric patients with the acute respiratory distress syndrome. https://app.cochat.ai/papers/10.1097/00003246-199601000-00006
The paper
Gauger, P. G., Pranikoff, T., Schreiner, R. J., Moler, F. W., & Hirschl, R. B. (1996). Initial experience with partial liquid ventilation in pediatric patients with the acute respiratory distress syndrome. Critical Care Medicine. https://doi.org/10.1097/00003246-199601000-00006

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.