Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 461

The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.

Relationship between the humidity and temperature of inspired gas and the function of the airway mucosa

Williams, Robin, Rankin, Nigel, Smith, Tony, Galler, David, Seakins, Paul·1996·Critical Care Medicine

Abstract

OBJECTIVE: To review the available literature on the relationship between the humidity and temperature of inspired gas and airway mucosal function. DATA SOURCES: International computerized databases and published indices, experts in the field, conference proceedings, bibliographies. STUDY SELECTION/DATA EXTRACTION: Two hundred articles/texts on respiratory tract physiology and humidification were reviewed. Seventeen articles were selected from 40 articles for inclusion in the published data verification of the model. Selection was by independent reviewers. Extraction was by consensus, and was based on finding sufficient data. DATA SYNTHESIS: A relationship exists between inspired gas humidity and temperature, exposure time to a given humidity level, and mucosal function. This relationship can be modeled and represented as an inspired humidity magnitude vs. exposure time map. The model is predictive of mucosal function and can be partially verified by the available literature. It predicts that if inspired humidity deviates from an optimal level, a progressive mucosal dysfunction begins. The greater the humidity deviation, the faster the mucosal dysfunction progresses. CONCLUSIONS: A model for the relationship between airway mucosal dysfunction and the combination of the humidity of inspired gas and the duration over which the airway mucosa is exposed to that humidity is proposed. This model suggests that there is an optimal temperature and humidity above which, and below which, there is impaired mucosal function. This optimal level of temperature and humidity is core temperature and 100% relative humidity. However, existing data are only sufficient to test this model for gas conditions below core temperature and 100% relative humidity. These data concur with the model in that region. No studies have yet looked at this relationship beyond 24 hrs. Longer exposure times to any given level of inspired humidity and inspired gas temperatures and humidities above core temperature and 100% relative humidity need to be studied to fully verify the proposed model.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00003246-199611000-00025

Cites

23 of 23 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 23 references

Cited by

See all 461

Metadata

Authors
Williams, R., Rankin, N., Smith, T., Galler, D., & Seakins, P.
Venue
Critical Care Medicine
Published
1996-11
Volume
24
Issue
11
Pages
1920-1929
ISSN
0090-3493 (ISSN-L)
OpenAlex
W2004095802
Cited by
461
References
23
FWCI
3.24
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Relationship between the humidity and temperature of inspired gas and the function of the airway mucosa. https://app.cochat.ai/papers/10.1097/00003246-199611000-00025
The paper
Williams, R., Rankin, N., Smith, T., Galler, D., & Seakins, P. (1996). Relationship between the humidity and temperature of inspired gas and the function of the airway mucosa. Critical Care Medicine. https://doi.org/10.1097/00003246-199611000-00025

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.