CoChat

Oxygen delivery, oxygen consumption, and gastric intramucosal pH are not improved by a computer-controlled, closed-loop, vecuronium infusion in severe sepsis and septic shock

Freebairn, Ross C., Derrick, James, Gomersall, Charles D., Young, Robert J., Joynt, Gavin M. · 1997 · Critical Care Medicine
Cited by 57

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: To investigate the influence of the neuromuscular blocking agent vecuronium on oxygen delivery (DO2), oxygen consumption (VO2), oxygen extraction ratio, and gastric intramucosal pH in heavily sedated patients with severe sepsis or septic shock. DESIGN: Prospective, randomized, placebo-controlled, cross-over trial. SETTING: University hospital intensive care unit. PATIENTS: Eighteen mechanically ventilated patients with severe sepsis or septic shock. INTERVENTIONS: All patients were heavily sedated. After baseline measurement, a computer-controlled, closed-loop infusion of either vecuronium or saline was initiated and further measurements were made at 40 and 60 mins. The procedure was repeated with the alternative agent after return of neuromuscular function. MEASUREMENTS AND MAIN RESULTS: DO2, VO2, intramucosal pH were monitored using pulmonary artery catheters, a gas exchange monitor, and gastric tonometers. Changes from baseline were compared (paired t-test, p = .05). The vecuronium closed-loop infusion achieved T1 between 5% and 15% at 40 mins. There was a significant difference in the changes from baseline for static respiratory compliance in the vecuronium closed-loop infusion group compared with the saline closed-loop infusion group. There was no significant difference in the change from baseline for systemic or pulmonary vascular resistance, DO2, VO2, oxygen extraction ratio, or intramucosal pH. CONCLUSIONS: In these patients, vecuronium infusion achieved the targeted level of paralysis and improved respiratory compliance but did not alter intramucosal pH, VO2, DO2, or oxygen extraction ratios. With deep sedation, neuromuscular blockade in severe sepsis/septic shock does not significantly influence oxygen flux and should be abandoned as a routine method of improving tissue oxygenation in these patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00003246-199701000-00015

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 57

Metadata

Authors
Freebairn, R. C., Derrick, J., Gomersall, C. D., Young, R. J., & Joynt, G. M.
Venue
Critical Care Medicine
Published
1997-01
Volume
25
Issue
1
Pages
72-77
ISSN
0090-3493 (ISSN-L)
OpenAlex
W2023199839
Cited by
57
References
3
FWCI
4.55
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Oxygen delivery, oxygen consumption, and gastric intramucosal pH are not improved by a computer-controlled, closed-loop, vecuronium infusion in severe sepsis and septic shock. https://app.cochat.ai/papers/10.1097/00003246-199701000-00015
The paper
Freebairn, R. C., Derrick, J., Gomersall, C. D., Young, R. J., & Joynt, G. M. (1997). Oxygen delivery, oxygen consumption, and gastric intramucosal pH are not improved by a computer-controlled, closed-loop, vecuronium infusion in severe sepsis and septic shock. Critical Care Medicine. https://doi.org/10.1097/00003246-199701000-00015

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.