High-frequency oscillatory ventilation for adult respiratory distress syndrome-A pilot study

Fort, Peter, Farmer, Christopher, Westerman, Jan, Johannigman, Jay, Beninati, William, Dolan, Steven, Derdak, Stephen·1997·Critical Care Medicine

Abstract

OBJECTIVE: To evaluate the safety and effectiveness of high-frequency oscillatory ventilation using a protocol designed to recruit and maintain optimal lung volume in patients with severe adult respiratory distress syndrome (ARDS). SETTING: Surgical and medical intensive care units in a tertiary care, military teaching hospital. DESIGN: A prospective, clinical study. PATIENTS: Seventeen patients, 17 yrs to 83 yrs of age, with severe ARDS (Lung Injury Score of 3.81 +/- 0.23) failing inverse ratio mechanical conventional ventilation (PaO2/FiO2 ratio of 68.6 +/- 21.6, peak inspiratory pressure of 54.3 +/- 12.7 cm H2O, positive end-expiratory pressure of 18.2 +/- 6.9 cm H2O). INTERVENTIONS: High-frequency oscillatory ventilation was instituted after varying periods of conventional ventilation (5.12 +/- 4.3 days). We employed lung volume recruitment strategy that consisted of incremental increases in mean airway pressure to achieve a PaO2 of > or = 60 torr (> or = 8.0 kPa), with an FiO2 of < or = 0.6. MEASUREMENTS AND MAIN RESULTS: High-frequency oscillator ventilator settings (FiO2, mean airway pressure, pressure amplitude of oscillation [delta P] frequency) and hemodynamic parameters (cardiac output, oxygen delivery [DO2]), mean systemic and pulmonary arterial pressures, and the oxygenation index (oxygenation index = [FiO2 x mean airway pressure x 100]/PaO2) were monitored during the transition to high-frequency oscillatory ventilation and throughout the course of the high-frequency protocol. Thirteen patients demonstrated improved gas exchange and an overall improvement in PaO2/FiO2 ratio (p < .02). Reductions in the oxygenation index (p < .01) and FiO2 (p < .02) at 12, 24, and 48 hrs after starting high-frequency oscillatory ventilation were observed. No significant compromise in cardiac output or DO2 was observed, despite a significant increase in mean airway pressure (31.2 +/- 10.3 to 34.0 +/- 6.7 cm H2O, p < .05) on high-frequency oscillatory ventilation. The overall survival rate at 30 days was 47%. A greater number of pretreatment days on conventional ventilation (p < .009) and an entry oxygenation index of > 47 (sensitivity 100%, specificity 100%) were associated with mortality. CONCLUSIONS: High-frequency oscillatory ventilation is both safe and effective in adult patients with severe ARDS failing conventional ventilation. A lung volume recruitment strategy during high-frequency oscillatory ventilation produced improved gas exchange without a compromise in DO2. These results are encouraging and support the need for a prospective, randomized trial of algorithm-controlled conventional ventilation vs. high-frequency oscillatory ventilation for adults with severe ARDS.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00003246-199706000-00008

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 14 references

Cited by

See all 319

Metadata

Authors
Fort, P., Farmer, C., Westerman, J., Johannigman, J., Beninati, W., Dolan, S., & Derdak, S.
Venue
Critical Care Medicine
Published
1997-06
Volume
25
Issue
6
Pages
937-947
ISSN
0090-3493 (ISSN-L)
OpenAlex
W2010753913
Cited by
319
References
14
FWCI
15.46
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: High-frequency oscillatory ventilation for adult respiratory distress syndrome-A pilot study. https://app.cochat.ai/papers/10.1097/00003246-199706000-00008
The paper
Fort, P., Farmer, C., Westerman, J., Johannigman, J., Beninati, W., Dolan, S., & Derdak, S. (1997). High-frequency oscillatory ventilation for adult respiratory distress syndrome-A pilot study. Critical Care Medicine. https://doi.org/10.1097/00003246-199706000-00008

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.