Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 210

The DOI matches its Crossref record.

Effects of varying levels of positive end-expiratory pressure on intracranial pressure and cerebral perfusion pressure

McGuire, Glenn, Crossley, David, Richards, Jonathan, Wong, David · 1997 · Critical Care Medicine

Abstract

OBJECTIVE: To determine the influence of positive end-expiratory pressure (PEEP) on intracranial pressure and cerebral perfusion pressure. DESIGN: Neurosurgical intensive care patients requiring intracranial pressure monitoring and mechanical ventilation were studied in a randomized, controlled study. SETTING: Tertiary care, neurosurgical intensive care unit. PATIENTS: Eighteen patients were enrolled in the study. Patients had posttraumatic head injuries (n = 9), subarachnoid hemorrhage (n = 7), obstructive hydrocephalus (n = 1), and intracerebral hemorrhage of unknown cause (n = 1). INTERVENTIONS: Patients had PEEP levels of 5, 10, and 15 cm H2O applied to their lungs. MEASUREMENTS AND MAIN RESULTS: Changes in intracranial pressure, mean arterial pressure, and cerebral perfusion pressure were measured. The results were analyzed separately for patients with normal and increased intracranial pressure (> 15 mm Hg). PEEP at 5 cm H2O had no effect on intracranial pressure in the group with normal intracranial pressure. However, PEEP at 10 and 15 cm H2O produced a significant (p < .05) increase in intracranial pressure (1.9 and 1.5 mm Hg, respectively). In the group with increased intracranial pressure, no significant change in intracranial pressure occurred at any of the PEEP levels used. In both groups, cerebral perfusion pressure was unchanged throughout. CONCLUSIONS: In patients with normal intracranial pressure, PEEP at 5 cm H2O did not significantly alter intracranial pressure. The clinical relevance of the intracranial pressure increase at PEEP levels of 10 and 15 cm H2O is questionable because cerebral perfusion pressure did not change and remained > 60 mm Hg. In patients with increased intracranial pressure, higher levels of PEEP did not significantly change intracranial pressure or cerebral perfusion pressure.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00003246-199706000-00025

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 210

Metadata

Authors
McGuire, G., Crossley, D., Richards, J., & Wong, D.
Venue
Critical Care Medicine
Published
1997-06
Volume
25
Issue
6
Pages
1059-1062
ISSN
0090-3493 (ISSN-L)
OpenAlex
W2082437295
Cited by
210
References
0
FWCI
3.44
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effects of varying levels of positive end-expiratory pressure on intracranial pressure and cerebral perfusion pressure. https://app.cochat.ai/papers/10.1097/00003246-199706000-00025
The paper
McGuire, G., Crossley, D., Richards, J., & Wong, D. (1997). Effects of varying levels of positive end-expiratory pressure on intracranial pressure and cerebral perfusion pressure. Critical Care Medicine. https://doi.org/10.1097/00003246-199706000-00025

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.