Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 285

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

The Motor Activity Assessment Scale: A Valid and Reliable Sedation Scale For Use In Adult, Mechanically Ventilated, Surgical ICU Patients

Devlin, John W., Boleski, Gail, Mlynarek, Mark, Nerenz, David R., Peterson, Edward L., Horst, H. Mathilda, Zarowitz, Barbara J.·1998·Critical Care Medicine

Abstract

Society of Critical Care Medicine; 27th Educational and Scientific Symposium; San Antonio, Texas, USA; February 4-8, 1998: Oral Presentations: Pharmacologic Interventions in the ICU, Thursday, February 5, 1998 3: 00-4: 30 pm

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00003246-199801001-00011

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 285

Metadata

Authors
Devlin, J. W., Boleski, G., Mlynarek, M., Nerenz, D. R., Peterson, E. L., Horst, H. M., & Zarowitz, B. J.
Venue
Critical Care Medicine
Published
1998-01
Volume
26
Issue
Supplement
Pages
24A
ISSN
0090-3493 (ISSN-L)
OpenAlex
W1966837953
Cited by
285
References
1
Type
conference abstract
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Motor Activity Assessment Scale: A Valid and Reliable Sedation Scale For Use In Adult, Mechanically Ventilated, Surgical ICU Patients. https://app.cochat.ai/papers/10.1097/00003246-199801001-00011
The paper
Devlin, J. W., Boleski, G., Mlynarek, M., Nerenz, D. R., Peterson, E. L., Horst, H. M., & Zarowitz, B. J. (1998). The Motor Activity Assessment Scale: A Valid and Reliable Sedation Scale For Use In Adult, Mechanically Ventilated, Surgical ICU Patients. Critical Care Medicine. https://doi.org/10.1097/00003246-199801001-00011

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.