CoChat

Temperature measurement in critically ill orally intubated adults: A comparison of pulmonary artery core, tympanic, and oral methods

Giuliano, Karen K., Scott, Susan S., Elliot, Sheila, Giuliano, Anthony J. · 1999 · Critical Care Medicine
Cited by 120

The DOI matches its Crossref record.

Abstract

OBJECTIVE: Core temperature measurement using a pulmonary artery (PA) catheter is considered the gold standard for measuring temperatures in critically ill patients. The objective of this study was to compare oral and tympanic temperature measurements (in both the oral and core equivalence modes) against PA core temperature measurements to determine which method was the most accurate and reliable in the absence of a PA catheter. DESIGN: Prospective, descriptive comparative analysis. PATIENTS: Convenience sample of 102 critically ill orally intubated patients with a PA catheter in place. SETTING: A 24-bed medical/surgical/trauma intensive care unit in a university-affiliated medical center. INTERVENTIONS: Four experienced intensive care unit nurses were trained in the use of temperature measurement with the oral, tympanic (both core and oral equivalence modes were used), and PA core methods. Simultaneous temperature measurements were then taken once in each subject using each method. The potential covariates that were analyzed were mean blood pressure, patient acuity using the Simplified Acute Physiology Score II, age, sex, ambient room temperature, and ventilator circuit temperature. MEASUREMENTS AND MAIN RESULTS: The training period indicated that it took more time to train experienced nurses in the use of tympanic thermometry than oral thermometry. Descriptive statistics were the following: core, x = 37.33 (SD = 0.89); oral, x = 37.18 (SD = 0.92); tympanic oral, x = 36.80 (SD = 0.93); and tympanic core, x = 37.12 (SD = 1.0). Bias averages were calculated and were significantly different from 0 for all three methods (oral-PA core, -0.15 [SD = 0.36]; tympanic core-PA core, -0.11 [SD = 0.57], tympanic oral-PA core, -0.52 [SD = 0.53]), indicating that there is some degree of decreased accuracy associated with each method when compared with PA core. However, scatter plots using the Bland and Altman methodology (Altman DG, Bland JM: Practical Statistics for Medical Research. London, Chapman and Hall, 1991) illustrate that the greatest variability is associated with the tympanic method. CONCLUSIONS: Temperature measurement is an important piece of clinical data in a critically ill patient population. We found oral thermometry to be the most accurate and reproducible method when a PA core measurement was not available.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00003246-199910000-00020

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 120

Metadata

Authors
Giuliano, K. K., Scott, S. S., Elliot, S., & Giuliano, A. J.
Venue
Critical Care Medicine
Published
1999-10
Volume
27
Issue
10
Pages
2188-2193
ISSN
0090-3493 (ISSN-L)
OpenAlex
W2053005421
Cited by
120
References
0
FWCI
2.37
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Temperature measurement in critically ill orally intubated adults: A comparison of pulmonary artery core, tympanic, and oral methods. https://app.cochat.ai/papers/10.1097/00003246-199910000-00020
The paper
Giuliano, K. K., Scott, S. S., Elliot, S., & Giuliano, A. J. (1999). Temperature measurement in critically ill orally intubated adults: A comparison of pulmonary artery core, tympanic, and oral methods. Critical Care Medicine. https://doi.org/10.1097/00003246-199910000-00020

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.