Temperature measurement in critically ill orally intubated adults: A comparison of pulmonary artery core, tympanic, and oral methods
The DOI matches its Crossref record.
Abstract
OBJECTIVE: Core temperature measurement using a pulmonary artery (PA) catheter is considered the gold standard for measuring temperatures in critically ill patients. The objective of this study was to compare oral and tympanic temperature measurements (in both the oral and core equivalence modes) against PA core temperature measurements to determine which method was the most accurate and reliable in the absence of a PA catheter. DESIGN: Prospective, descriptive comparative analysis. PATIENTS: Convenience sample of 102 critically ill orally intubated patients with a PA catheter in place. SETTING: A 24-bed medical/surgical/trauma intensive care unit in a university-affiliated medical center. INTERVENTIONS: Four experienced intensive care unit nurses were trained in the use of temperature measurement with the oral, tympanic (both core and oral equivalence modes were used), and PA core methods. Simultaneous temperature measurements were then taken once in each subject using each method. The potential covariates that were analyzed were mean blood pressure, patient acuity using the Simplified Acute Physiology Score II, age, sex, ambient room temperature, and ventilator circuit temperature. MEASUREMENTS AND MAIN RESULTS: The training period indicated that it took more time to train experienced nurses in the use of tympanic thermometry than oral thermometry. Descriptive statistics were the following: core, x = 37.33 (SD = 0.89); oral, x = 37.18 (SD = 0.92); tympanic oral, x = 36.80 (SD = 0.93); and tympanic core, x = 37.12 (SD = 1.0). Bias averages were calculated and were significantly different from 0 for all three methods (oral-PA core, -0.15 [SD = 0.36]; tympanic core-PA core, -0.11 [SD = 0.57], tympanic oral-PA core, -0.52 [SD = 0.53]), indicating that there is some degree of decreased accuracy associated with each method when compared with PA core. However, scatter plots using the Bland and Altman methodology (Altman DG, Bland JM: Practical Statistics for Medical Research. London, Chapman and Hall, 1991) illustrate that the greatest variability is associated with the tympanic method. CONCLUSIONS: Temperature measurement is an important piece of clinical data in a critically ill patient population. We found oral thermometry to be the most accurate and reproducible method when a PA core measurement was not available.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Design, Analysis, and Interpretation of Method-Comparison Studies
Hanneman, S. K. (2008) · AACN Advanced Critical Care · doi:10.1097/01.aacn.0000318125.41512.a3 · Cited by 306
Lefrant, J.-Y., Muller, L., de La Coussaye, J. E., Benbabaali, M., Lebris, C., Zeitoun, N., Mari, C., Saïssi, G., Ripart, J., & Eledjam, J.-J. (2003) · Intensive Care Medicine · doi:10.1007/s00134-002-1619-5 · Cited by 303
Hoedemaekers, C. W., Ezzahti, M., Gerritsen, A., & van der Hoeven, J. G. (2007) · Critical Care · doi:10.1186/cc6104 · Cited by 293
Niven, D. J., Gaudet, J. E., Laupland, K. B., Mrklas, K. J., Roberts, D. J., & Stelfox, H. T. (2015) · Annals of Internal Medicine · doi:10.7326/m15-1150 · Cited by 240
Thermometry in paediatric practice
El-Radhi, A. S. (2006) · Archives of Disease in Childhood · doi:10.1136/adc.2005.088831 · Cited by 160
Metadata
- Authors
- Giuliano, K. K., Scott, S. S., Elliot, S., & Giuliano, A. J.
- Venue
- Critical Care Medicine
- Published
- 1999-10
- Volume
- 27
- Issue
- 10
- Pages
- 2188-2193
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W2053005421
- Cited by
- 120
- References
- 0
- FWCI
- 2.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Temperature measurement in critically ill orally intubated adults: A comparison of pulmonary artery core, tympanic, and oral methods. https://app.cochat.ai/papers/10.1097/00003246-199910000-00020
- The paper
- Giuliano, K. K., Scott, S. S., Elliot, S., & Giuliano, A. J. (1999). Temperature measurement in critically ill orally intubated adults: A comparison of pulmonary artery core, tympanic, and oral methods. Critical Care Medicine. https://doi.org/10.1097/00003246-199910000-00020
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.