CoChat

A prospective study of the use of a dobutamine stress test to identify outcome in patients with sepsis, severe sepsis, or septic shock

Rhodes, Andrew, Lamb, Fiona J., Malagon, Ignazio, Newman, Philip J., Grounds, R. Michael, Bennett, E. David · 1999 · Critical Care Medicine
Cited by 118

The DOI matches its Crossref record.

Abstract

OBJECTIVE: To more clearly define the relationship between an oxygen flux test, oxygen supply dependency, and outcome in patients with sepsis, severe sepsis, or septic shock. DESIGN: Prospective, interventional clinical trial. SETTING: A teaching hospital general intensive care unit in London, UK. PATIENTS: A total of 36 patients with sepsis, severe sepsis, or septic shock were studied during a 10-month period. INTERVENTIONS: After resuscitation, patients were given an intravenous infusion of dobutamine at 10 microg/kg/min for 1 hr. Cardiac and respiratory variables were measured before the infusion and then while the infusion was in progress. Any patient who was able to increase his or her oxygen consumption by >15% was designated a responder to the test. MEASUREMENTS AND MAIN RESULTS: Hemodynamic, oxygen transport, and lactate measurements were made at baseline and after 1 hr of the dobutamine infusion. All patients were then followed up until hospital discharge. Responders to this test had a hospital mortality of 14%, whereas nonresponders had a mortality of 91% (p<.01). The responders were characterized by being younger (p<.05), having higher Acute Physiology and Chronic Health Evaluation III scores (p<.05), and having a greater requirement for inotropic support (p<.05). After the test, the responders had significantly higher oxygen delivery (p<.01) and oxygen consumption (p<.05) than the nonresponders, as well as a significantly greater temperature increase as a result of the infusion (p<.05). The nonresponders were unable to increase either oxygen delivery or oxygen consumption to the dobutamine. This test was highly predictive of outcome (p<.0001). The identification of an increase in both oxygen delivery and oxygen consumption (oxygen supply dependency) was not associated with a poor outcome. CONCLUSION: A dobutamine oxygen flux test provides evidence of the intrinsic function of cells. The inability of these cells to increase oxidative metabolism during sepsis, as indicated by the dobutamine test, is associated with a high mortality.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00003246-199911000-00007

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 118

Metadata

Authors
Rhodes, A., Lamb, F. J., Malagon, I., Newman, P. J., Grounds, R. M., & Bennett, E. D.
Venue
Critical Care Medicine
Published
1999-11
Volume
27
Issue
11
Pages
2361-2366
ISSN
0090-3493 (ISSN-L)
OpenAlex
W2037099101
Cited by
118
References
0
FWCI
5.36
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A prospective study of the use of a dobutamine stress test to identify outcome in patients with sepsis, severe sepsis, or septic shock. https://app.cochat.ai/papers/10.1097/00003246-199911000-00007
The paper
Rhodes, A., Lamb, F. J., Malagon, I., Newman, P. J., Grounds, R. M., & Bennett, E. D. (1999). A prospective study of the use of a dobutamine stress test to identify outcome in patients with sepsis, severe sepsis, or septic shock. Critical Care Medicine. https://doi.org/10.1097/00003246-199911000-00007

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.