CoChat

Accidental removal of endotracheal and nasogastric tubes and intravascular catheters

Carrión, María Isabel, Ayuso, Diego, Marcos, Monserrat, Robles, María Paz, de la Cal, Miguel A., Alía, Inmaculada, Esteban, Andrés · 2000 · Critical Care Medicine
Cited by 143

The DOI matches its Crossref record.

Abstract

OBJECTIVES: To characterize the rates of accidental removal of endotracheal tubes, nasogastric tubes, central venous catheters, and arterial catheters. To assess the efficacy of corrective measures aimed at reducing the accidental removal of these devices. DESIGN: Prospective, observational, and interventional study. SETTING: Eighteen-bed medical-surgical intensive care unit of a 650-bed tertiary care hospital. PATIENTS: Patients admitted to the intensive care unit who had any of the following devices in place for more than 24 hrs: endotracheal tube, nasogastric tube, central venous catheter, arterial catheter. MEASUREMENTS AND INTERVENTIONS: Data were collected on the date of placement of tubes and catheters, position of vascular catheters, date of removal, and reason for removal. The study involved three consecutive 6-month periods. At the end of the first and the second periods, information about rates of accidental removal was provided to the physicians and nurses. In addition, the personnel were instructed to be more vigilant and specific measures aimed at reducing the accidental removal were introduced. MAIN RESULTS: In the first period, 289 endotracheal tubes were placed and 13.1% (24.7 per 1000 days) were removed accidentally. In the second and third periods, 17.1% (25.5 per 1000 days) and 11.4% (15.1 per 1000 days) were removed accidentally, respectively. In the first period, 368 nasogastric tubes were placed and 41% (73.9 per 1000 days) were removed accidentally. In both the second and the third period, a significant reduction in the rate of accidental removal was observed (32.4% or 41.2 per 1000 days and 25.8% or 29.8 per 1000 days, respectively). A significant decrease was observed in the rates of accidental removal of central venous catheters from 7.5% (12.4 per 1000 days) in the first period to 3.6% (5.4 per 1000 days) in the second period. The rate of arterial catheters accidentally removed expressed according to the time at risk significantly decreased from 46.5 per 1000 days in the first period to 19.1 per 1000 days in the second period and 25.3 per 1000 days in the third period. CONCLUSIONS: The information provided by the rates of accidental removal expressed by patient-days is helpful to compare results obtained in populations with different times of follow-up. Education of medical personnel and limiting upper-extremity access to within 20 cm from any catheter or tube resulted in a significant reduction of patient-related removal of tubes and catheters.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00003246-200001000-00010

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 143

Metadata

Authors
Carrión, M. I., Ayuso, D., Marcos, M., Robles, M. P., de la Cal, M. A., Alía, I., & Esteban, A.
Venue
Critical Care Medicine
Published
2000-01
Volume
28
Issue
1
Pages
63-66
ISSN
0090-3493 (ISSN-L)
OpenAlex
W2080924244
Cited by
143
References
0
FWCI
12.17
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Accidental removal of endotracheal and nasogastric tubes and intravascular catheters. https://app.cochat.ai/papers/10.1097/00003246-200001000-00010
The paper
Carrión, M. I., Ayuso, D., Marcos, M., Robles, M. P., de la Cal, M. A., Alía, I., & Esteban, A. (2000). Accidental removal of endotracheal and nasogastric tubes and intravascular catheters. Critical Care Medicine. https://doi.org/10.1097/00003246-200001000-00010

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.