Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 316

The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.

Physiologic evaluation of noninvasive mechanical ventilation delivered with three types of masks in patients with chronic hypercapnic respiratory failure

Navalesi, Paolo, Fanfulla, Francesco, Frigerio, Pamela, Gregoretti, Cesare, Nava, Stefano·2000·Critical Care Medicine

Abstract

OBJECTIVE: The efficacy of noninvasive mechanical ventilation (NIMV) in improving breathing pattern and arterial blood gases (ABG) in hypercapnic patients has been well documented; however, little attention has been given to the choice of the interface and the ventilatory mode. We evaluated the effects of three types of masks and two modes of ventilation on patients' ABG, breathing pattern, and tolerance to ventilation. DESIGN: Prospective randomized study. SETTING: Two respiratory weaning centers. PATIENTS: A total of 26 stable hypercapnic patients (pH, 7.38 +/- 0.04; PaCO2, 59.2. +/- 10.9 torr) had not received NIMV and were affected by restrictive thoracic disease or obstructive pulmonary disease. INTERVENTIONS: Three 30-min runs of NIMV, delivered using volume-assisted (n = 13) or pressure-assisted modes of partial mechanical support (n = 13), were performed in random order with a full-face mask, a nasal mask, and nasal plugs. MEASUREMENTS: ABG, breathing pattern, and patients' tolerance to ventilation. MAIN RESULTS: Compared with spontaneous breathing, the application of NIMV significantly improved ABG and minute ventilation, irrespective of the ventilatory mode, the underlying pathology or the type of mask. Overall, a nasal mask was better tolerated than the other two interfaces (p < .005 vs. nasal plugs and full-face mask). PaCO2 was significantly lower (p < .01) with a full-face mask or nasal plugs than with a nasal mask (49.5 +/- 9.4 torr, 49.7 +/- 8 torr, and 52.4 +/- 11 torr, respectively). Minute ventilation was significantly higher with a full-face mask than with a nasal mask because of an increase in tidal volume. No differences were observed in tolerance to ventilation, ABG, or breathing pattern, using assist control or pressure-assisted modes. CONCLUSIONS: In this physiologic study, we have shown that in patients with hypercapnic respiratory failure, irrespective of the underlying pathology, the type of interface affects the NIMV outcome more than the ventilatory mode.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00003246-200006000-00015

Cites

25 of 25 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 25 references

Cited by

See all 316

Metadata

Authors
Navalesi, P., Fanfulla, F., Frigerio, P., Gregoretti, C., & Nava, S.
Venue
Critical Care Medicine
Published
2000-06
Volume
28
Issue
6
Pages
1785-1790
ISSN
0090-3493 (ISSN-L)
OpenAlex
W2063756800
Cited by
316
References
25
FWCI
14.31
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Physiologic evaluation of noninvasive mechanical ventilation delivered with three types of masks in patients with chronic hypercapnic respiratory failure. https://app.cochat.ai/papers/10.1097/00003246-200006000-00015
The paper
Navalesi, P., Fanfulla, F., Frigerio, P., Gregoretti, C., & Nava, S. (2000). Physiologic evaluation of noninvasive mechanical ventilation delivered with three types of masks in patients with chronic hypercapnic respiratory failure. Critical Care Medicine. https://doi.org/10.1097/00003246-200006000-00015

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.