Effects of guidelines implementation in a surgical intensive care unit to control nighttime light and noise levels

Walder, Bernhard, Francioli, David, Meyer, Jean-Jacques, Lançon, Michel, Romand, Jacques-A.·2000·Critical Care Medicine

Abstract

OBJECTIVE: Because of around-the-clock activities, environmental noise and light are among the many causes of sleep disturbance in an intensive care unit (ICU). The implementation of guidelines may potentially change behavior rules and improve sleep quality. DESIGN: A prospective interventional study, observing the effects of simple nighttime guidelines on light and noise levels in an ICU. SETTING: A modern surgical ICU, subdivided into six identical three-bed rooms. PATIENTS: Critically ill adult patients. INTERVENTION: Between two observation periods, five guidelines were implemented to decrease both light and noise during the night shift in the patient's room. MEASUREMENT: Light levels and noise levels were obtained using a luxmeter and a sound level meter [A-weighted decibels (dB) scale] and were monitored continuously from 11 pm to 5 am both before (period P1) and after (period P2) the implementation of guidelines. MAIN RESULTS: Similar patient's gravity and nursing workload scores were observed between P1 and P2. A low mean (<5 Lux) and maximal light level were measured during both P1 and P2. The implementation of guidelines lowered mean light disturbance intensity with a greater variability of light during P2. All noise levels were high and corresponded more to a quiet office for noise level equivalents and to a busy restaurant for peak noise levels during both P1 and P2. Guidelines decreased the noise level equivalent (P1, 51.3 dB; P2, 48.3 dB), peak noise level (P1, 74.9 dB; P2, 70.8 dB), and the number of acoustic identified alarms (P1, 22.1 dB; P2, 15.8 dB) during P2. CONCLUSION: The night light levels were low during both periods, and lowering the light levels induced a greater variation of light, which may impair sleep quality. All measured noise levels were high during both periods, which could contribute to sleep disturbance, and the implementation of guidelines significantly lowers some important noise levels. The background noise level was unchanged.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00003246-200007000-00010

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 170

Metadata

Authors
Walder, B., Francioli, D., Meyer, J.-J., Lançon, M., & Romand, J.-A.
Venue
Critical Care Medicine
Published
2000-07
Volume
28
Issue
7
Pages
2242-2247
ISSN
0090-3493 (ISSN-L)
OpenAlex
W2066574717
Cited by
170
References
1
FWCI
3.16
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effects of guidelines implementation in a surgical intensive care unit to control nighttime light and noise levels. https://app.cochat.ai/papers/10.1097/00003246-200007000-00010
The paper
Walder, B., Francioli, D., Meyer, J.-J., Lançon, M., & Romand, J.-A. (2000). Effects of guidelines implementation in a surgical intensive care unit to control nighttime light and noise levels. Critical Care Medicine. https://doi.org/10.1097/00003246-200007000-00010

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.