The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Adrenal insufficiency during septic shock*
Abstract
OBJECTIVE: To determine whether a baseline (random) cortisol concentration <25 microg/dL in patients with septic shock was a better discriminator of adrenal insufficiency than the standard (250 microg) and the low-dose (1 microg) corticotropin stimulation tests as assessed by the hemodynamic response to steroid replacement. SETTING: Intensive care unit. PATIENTS: Fifty-nine patients with septic shock. Their mean age was 57 +/- 16.7 yrs; 29 were male. INTERVENTIONS: A baseline cortisol concentration was obtained. Patients then received an intravenous injection of 1 microg of corticotropin (low-dose test) followed 60 mins later by an injection of 249 microg of corticotropin (high-dose test). Cortisol concentrations were obtained 30 and 60 mins after low- and high-dose corticotropin. All patients were administered hydrocortisone (100 mg every 8 hrs) for the first 24 hrs while awaiting results of cortisol assessment. Patients were considered steroid responsive if the pressor agent could be discontinued within 24 hrs of the first dose of hydrocortisone. MEASUREMENTS AND MAIN RESULTS: Forty-seven percent of patients died. Twenty-two percent of patients met the diagnostic criteria of adrenal insufficiency by the low-dose test and 8% by the high-dose test. However, 61% of patients met the criteria of adrenal insufficiency when we used a baseline cortisol concentration of <25 microg/dL. Twenty-two patients (37%) were steroid responsive; the baseline serum cortisol was 14.1 +/- 5.2 microg/dL in the steroid-responsive patients compared with 33.3 +/- 18 microg/dL in the steroid-nonresponsive patients (p <.0001). Ninety-five percent of steroid-responsive patients had a baseline cortisol concentration <25 microg/dL. Fifty-four percent of steroid responders had a diagnostic low-dose test and 22% a diagnostic high-dose test. Receiver operating characteristic curve analysis revealed that a stress cortisol concentration of 23.7 microg/dL was the most accurate diagnostic threshold for determination of the hemodynamic response to glucocorticoid therapy. CONCLUSIONS: Adrenal insufficiency is common in patients with septic shock, the incidence depending largely on the diagnostic test and criteria used to make the diagnosis. There is clearly no absolute serum cortisol concentration that distinguishes an adequate from an insufficient adrenal response. However, we believe that a random cortisol concentration of <25 microg/dL in a highly stressed patient is a useful diagnostic threshold for the diagnosis of adrenal insufficiency.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Annane, D. (2000) · JAMA · doi:10.1001/jama.283.8.1038 · Cited by 1,000 · cited 1×
“(44) and other investigators have used an absolute increase in cortisol ( max) of 9 g/dL following an HD test to be diagnostic of “occult adrenal insufficiency.”
BackgroundOelkers, W. (1996) · New England Journal of Medicine · doi:10.1056/nejm199610173351607 · Cited by 737
JÄÄTTELÄ, M., ILVESMÄKI, V., VOUTILAINEN, R., STENMAN, U.-H., & SAKSELA, E. (1991) · Endocrinology · doi:10.1210/endo-128-1-623 · Cited by 243
Comparison of low and high dose corticotropin stimulation tests in patients with pituitary disease
Mayenknecht, J., Diederich, S., Bähr, V., Plöckinger, U., & Oelkers, W. (1998) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem.83.5.4831 · Cited by 142
Pariante, C. M., Pearce, B. D., Pisell, T. L., Sanchez, C. I., Po, C., Su, C., & Miller, A. H. (1999) · Endocrinology · doi:10.1210/en.140.9.4359 · Cited by 40
Cited by
Marik, P. E., Pastores, S. M., Annane, D., Meduri, G. U., Sprung, C. L., Arlt, W., Keh, D., Briegel, J., Beishuizen, A., Dimopoulou, I., et al. (2008) · Critical Care Medicine · doi:10.1097/ccm.0b013e31817603ba · Cited by 912
Self-citationDiagnosis of Adrenal Insufficiency in Severe Sepsis and Septic Shock
Annane, D., Maxime, V., Ibrahim, F., Alvarez, J. C., Abe, E., & Boudou, P. (2006) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200509-1369oc · Cited by 327
Critical Illness-Related Corticosteroid Insufficiency
Marik, P. E. (2009) · Chest · doi:10.1378/chest.08-1149 · Cited by 299
Self-citationCortisol Response in Relation to the Severity of Stress and Illness
Widmer, I. E., Puder, J. J., König, C., Pargger, H., Zerkowski, H. R., Girard, J., & Müller, B. (2005) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2005-0354 · Cited by 225
Adrenal insufficiency in critical illness
Cooper, M. S., & Stewart, P. M. (2007) · Journal of Intensive Care Medicine · doi:10.1177/0885066607307832 · Cited by 97
Magnotti, M., & Shimshi, M. (2008) · Endocrine Practice · doi:10.4158/ep.14.2.233 · Cited by 62
Vassiliadi, D. A., Dimopoulou, I., Tzanela, M., Douka, E., Livaditi, O., Orfanos, S. E., Kotanidou, A., & Tsagarakis, S. (2014) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2014-2619 · Cited by 32
Hypothyroidism and Adrenal Insufficiency in Sepsis and Hemorrhagic Shock
Ho, H. C. (2004) · Archives of Surgery · doi:10.1001/archsurg.139.11.1199 · Cited by 25
Diagnosis of adrenal failure in critically ill patients
Moraes, R. B., Czepielewski, M. A., Friedman, G., & Borba, E. L. D. (2011) · Arquivos Brasileiros de Endocrinologia & Metabologia · doi:10.1590/s0004-27302011000500001 · Cited by 20
“Another study published in 2005 (26), which defined unresponsive patients to low dose test as showing cortisol variation ≤ 9 μg/dL, exhibited an interesting result.”
Background
Metadata
- Authors
- Marik, P. E., & Zaloga, G. P.
- Venue
- Critical Care Medicine
- Published
- 2003-01
- Volume
- 31
- Issue
- 1
- Pages
- 141-145
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W2166962064
- Cited by
- 379
- References
- 5
- FWCI
- 24.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.