The DOI matches its Crossref record.
A Guide to the Effective Use of Otoacoustic Emissions
Abstract
Otoacoustic emission test instruments are now entering routine audiological practice. Two general classes of technique are in use in laboratory work--those employing spectrum analysers to observe the continuous generation of OAEs, both stimulated or unstimulated, and those using transient stimulation and waveform averaging to extract a delayed OAE or "cochlear echo" waveform from ear canal sound. Both methods have particular advantages in clinical applications. The transient OAE type of method has proved very effective in screening applications, particularly in neonates. It is possible to perform noninvasive screening acoustic cochleography in about a minute. The technique is also useful for characterizing cochlear mechanical status prior to long term monitoring. Achieving routinely reliable OAE test performance in clinical and screening applications under nonideal conditions makes special demands on the instrumental design and the response evaluation procedures. The essential requirements are reviewed and discussed in a general and specific context. We have tried to meet these requirements in a transient evoked otoacoustic emission system (the ILO88) which we designed to operate with a personal computer. We report on our design of probe, and our use of evaluation procedures for probe fit, and response quality. Signal processing methods have been developed to reject noncochlear acoustic responses, and to optimise the rejection of patient noise. Examples of its clinical use, and the practical problems typically encountered are given here.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Starr, A., Picton, T. W., Sininger, Y., Hood, L. J., & Berlin, C. I. (1996) · Brain · doi:10.1093/brain/119.3.741 · Cited by 988
Distortion product otoacoustic emissions during the first year in term infants: A longitudinal study
Zang, Z., & Jiang, Z. D. (2007) · Brain and Development · doi:10.1016/j.braindev.2006.10.001 · Cited by 162
Metadata
- Authors
- Kemp, D. T., Ryan, S., & Bray, P.
- Venue
- Ear and Hearing
- Published
- 1990-04
- Volume
- 11
- Issue
- 2
- Pages
- 93-105
- ISSN
- 0196-0202 (ISSN-L)
- OpenAlex
- W2048490699
- Cited by
- 621
- References
- 0
- FWCI
- 12.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Guide to the Effective Use of Otoacoustic Emissions. https://app.cochat.ai/papers/10.1097/00003446-199004000-00004
- The paper
- Kemp, D. T., Ryan, S., & Bray, P. (1990). A Guide to the Effective Use of Otoacoustic Emissions. Ear and Hearing. https://doi.org/10.1097/00003446-199004000-00004
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.