The DOI matches its Crossref record.
Speech Recognition with the Nucleus 24 SPEAK, ACE, and CIS Speech Coding Strategies in Newly Implanted Adults
Abstract
OBJECTIVE: The objective of this study was to determine whether 1) the SPEAK, ACE or CIS speech coding strategy was associated with significantly better speech recognition for individual subjects implanted with the Nucleus CI24M internal device who used the SPrint speech processor, and 2) whether a subject's preferred strategy for use in everyday life provided the best speech recognition. DESIGN: Twelve postlinguistically deaf, newly implanted adults participated. Initial preference for the three strategies was obtained with paired-comparison testing on the first day of implant stimulation with seven of eight U.S. subjects. During the first 12 wk, all subjects used each strategy alone for 4 wk to give them experience with the strategy and to identify preferred speech processor program parameters and settings that would be used in subsequent testing. For the next 6 wk, subjects used one strategy at a time for 2-wk intervals in the same order they had for the first 12 wk. At the end of each 2-wk interval, speech recognition testing was conducted with all three strategies. At the end of the 6 wk, all three strategies were placed on each subject's processor, and subjects were asked to compare listening with these three programs in as many situations as possible for the next 2 wk. When they returned, subjects responded to a questionnaire asking about their preferred strategy and responded to two lists of medial consonants using each of the three strategies. The U.S. subjects also responded to two lists of medial vowels with the three strategies. RESULTS: Six of the 12 subjects in the present study had significantly higher CUNY sentence scores with the ACE strategy than with one or both of the other strategies; one of the 12 subjects had a significantly higher score with SPEAK than with ACE. In contrast, only two subjects had significantly higher CNC word and phoneme scores with one or two strategies than with the third strategy. One subject had a significantly higher vowel score with the SPEAK strategy than with the CIS strategy; and no subjects had significantly higher consonant scores with any strategy. Seven of 12 subjects preferred the ACE strategy, three preferred the SPEAK strategy, and two preferred the CIS strategy. Subjects' responses on a questionnaire agreed closely with strategy preference from comparisons made in everyday life. There was a strong relation between the preferred strategy and scores on CUNY sentences but not for the other speech tests. For all subjects, except one, the preferred strategy was the one with the highest CUNY sentence score or was a strategy with a CUNY score not significantly lower than the highest score. CONCLUSIONS: Despite differences in research design, there was remarkably close agreement in the pattern of group mean scores for the three strategies for CNC words and CUNY sentences in noise between the present study and the Conversion study (Arndt, Staller, Arcaroli, Hines, & Ebinger, Reference Note 1). In addition, essentially the same percentage of subjects preferred each strategy. For both studies, the strategy with which subjects had the highest score on the CUNY sentences in noise evaluation was strongly related to the preferred strategy; this relation was not strong for CNC words, CNC phonemes, vowels or consonants (Skinner, Arndt, & Staller, 2002). These results must be considered within the following context. For each strategy, programming parameters preferred for use in everyday life were determined before speech recognition was evaluated. In addition, implant recipients had experience listening with all three strategies in many situations in everyday life before choosing a preferred strategy. Finally, 11 of the 12 subjects strongly preferred one of the three strategies. Given the results and research design, it is recommended that clinicians fit each strategy sequentially starting with the ACE strategy so that the preferred programming parameters are determined for each strategy before recipients compare pairs of strategies. The goal is to provide the best opportunity for individuals to hear in everyday life within a clinically acceptable time period (e.g., 6 wk).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Role of Electrode Placement as a Contributor to Variability in Cochlear Implant Outcomes
Finley, C. C., Holden, T. A., Holden, L. K., Whiting, B. R., Chole, R. A., Neely, G. J., Hullar, T. E., & Skinner, M. W. (2008) · Otology & Neurotology · doi:10.1097/mao.0b013e318184f492 · Cited by 549
Self-citationSpeech recognition with amplitude and frequency modulations
Zeng, F.-G., Nie, K., Stickney, G. S., Kong, Y.-Y., Vongphoe, M., Bhargave, A., Wei, C., & Cao, K. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0406460102 · Cited by 383
Prado-Guitierrez, P., Fewster, L. M., Heasman, J. M., McKay, C. M., & Shepherd, R. K. (2006) · Hearing Research · doi:10.1016/j.heares.2006.03.006 · Cited by 173
Metadata
- Authors
- Skinner, M. W., Holden, L. K., Whitford, L. A., Plant, K. L., Psarros, C., & Holden, T. A.
- Venue
- Ear and Hearing
- Published
- 2002-06
- Volume
- 23
- Issue
- 3
- Pages
- 207-223
- ISSN
- 0196-0202 (ISSN-L)
- OpenAlex
- W2001037387
- Cited by
- 164
- References
- 0
- FWCI
- 3.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Speech Recognition with the Nucleus 24 SPEAK, ACE, and CIS Speech Coding Strategies in Newly Implanted Adults. https://app.cochat.ai/papers/10.1097/00003446-200206000-00005
- The paper
- Skinner, M. W., Holden, L. K., Whitford, L. A., Plant, K. L., Psarros, C., & Holden, T. A. (2002). Speech Recognition with the Nucleus 24 SPEAK, ACE, and CIS Speech Coding Strategies in Newly Implanted Adults. Ear and Hearing. https://doi.org/10.1097/00003446-200206000-00005
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.