The DOI matches its Crossref record.
Statistical Measures of the Lower Limit of Detection of a Radioactivity Counter
Abstract
The lower limit of detection of a counter is best expressed statistically in terms of two minimal activities determined by the maximal acceptable risks of making a Type I error (of concluding there is sample activity when there is none) and a Type II error (of concluding there is no activity in the sample when there is some). These threshold activities are designated “the minimum significant measured activity”, defined to be the smallest measurement which is interpreted as meaning there is activity in the sample, and “the minimum detectable true activity”, defined to be the smallest amount of activity required to be in a sample in order that a measurement can be expected to imply correctly the presence of activity with a predetermined degree of confidence. It is to be noted that the former refers to a measurement while the latter refers to the actual activity present. This paper is concerned with the statistical problems of the definition and derivation of these two measures of detection sensitivity. Though either quantity can serve equally well as a measure of detection threshold, it is important to recognize the distinction between the threshold for measured activity and the, threshold for true activity and their different applications the former dealing with measurements meriting being reported as greater than zero and the latter with the amount of actual activity that can be detected with predetermined confidence.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Limits for qualitative detection and quantitative determination. Application to radiochemistry
Currie, L. A. (1968) · Analytical Chemistry · doi:10.1021/ac60259a007 · Cited by 4,553
Vogel, T. M., & McCarty, P. L. (1985) · Applied and Environmental Microbiology · doi:10.1128/aem.49.5.1080-1083.1985 · Cited by 485
Transformation of toluene and benzene by mixed methanogenic cultures
Grbić-Galić, D., & Vogel, T. M. (1987) · Applied and Environmental Microbiology · doi:10.1128/aem.53.2.254-260.1987 · Cited by 458
Bouwer, E. J., & McCarty, P. L. (1983) · Applied and Environmental Microbiology · doi:10.1128/aem.45.4.1286-1294.1983 · Cited by 428
Metadata
- Authors
- Altshuler, B., & Pasternack, B.
- Venue
- Health Physics
- Published
- 1963-03
- Volume
- 9
- Issue
- 3
- Pages
- 293-298
- ISSN
- 0017-9078 (ISSN-L)
- OpenAlex
- W2025156606
- Cited by
- 172
- References
- 0
- FWCI
- 2.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Statistical Measures of the Lower Limit of Detection of a Radioactivity Counter. https://app.cochat.ai/papers/10.1097/00004032-196303000-00005
- The paper
- Altshuler, B., & Pasternack, B. (1963). Statistical Measures of the Lower Limit of Detection of a Radioactivity Counter. Health Physics. https://doi.org/10.1097/00004032-196303000-00005
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.