PHYSICAL MODELS AND DOSE FACTORS FOR USE IN INTERNAL DOSE ASSESSMENT
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Internal dose assessment depends on the use of mathematical formulas for dose calculation and models of the human body and its organs. A simple, unified method for internal dose calculations is described, which brings together and simplifies concepts used in nuclear medicine and occupational internal dose systems previously described. Using the best current decay data and phantoms for internal dose calculations, dose factors for internal dose assessment are provided. Decay data for over 800 radionuclides from the data service at Brookhaven National Laboratory were combined with absorbed fraction data from a number of currently available mathematical whole body and organ models to provide the dose factors. This represents the first published update on nuclear medicine dose factors since MIRD Pamphlet No. 11 in 1975; in this paper, dose factors for many more nuclides are given (816 vs. 117 in MIRD 11), including some alpha emitters. New models are also employed, and dose factors for bone and marrow have been updated with recently suggested corrections. The good agreement of the new dose factors with previously published values for several of the models gives good confidence in their accuracy. This article gives an overview of the technical basis for these dose factors and some example tables of data, but the bulk of the data files will be distributed electronically. The use of an "electronic publishing" approach permits the publication of this kind of voluminous information in mainstream journals while facilitating rapid access and use without the need to purchase often expensive and bulky paper documents.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Computerized three‐dimensional segmented human anatomy
Zubal, I. G., Harrell, C. R., Smith, E. O., Rattner, Z., Gindi, G., & Hoffer, P. B. (1994) · Medical Physics · doi:10.1118/1.597290 · Cited by 1,103
MIRDOSE: Personal Computer Software for Internal Dose Assessment in Nuclear Medicine
Piwnica-Worms, D. (1996) · Cited by 500
On the Equivalent Dose for Auger Electron Emitters
Howell, R. W., Narra, V. R., Sastry, K. S. R., & Rao, D. V. (1993) · Radiation Research · doi:10.2307/3578503 · Cited by 62
Chord distributions across 3D digital images of a human thoracic vertebra
Jokisch, D. W., Patton, P. W., Rajon, D. A., Inglis, B. A., & Bolch, W. E. (2001) · Medical Physics · doi:10.1118/1.1380211 · Cited by 26
Stabin, M. G., Siegel, J. A., & Sparks, R. B. (2002) · Cancer Biotherapy and Radiopharmaceuticals · doi:10.1089/108497802760804763 · Cited by 25
Self-citationEnergy Distribution and the Relative Biological Effects of Internal Alpha Emitters
Fisher, D. R., Frazier, M., & Andrews, T. K. J. (1985) · Radiation Protection Dosimetry · doi:10.1093/rpd/13.1-4.223 · Cited by 25
Cited by
Wong, D. F., Rosenberg, P. B., Zhou, Y., Kumar, A., Raymont, V., Ravert, H. T., Dannals, R. F., Nandi, A., Brašić, J. R., Ye, W., et al. (2010) · Journal of Nuclear Medicine · doi:10.2967/jnumed.109.069088 · Cited by 684
“Time integrals of activity (18) were entered into the OLINDA/EXM software (19) using the adult male model.”
MethodLee, H., Shields, A. F., Siegel, B. A., Miller, K. D., Krop, I., Ma, C. X., LoRusso, P. M., Munster, P. N., Campbell, K., Gaddy, D. F., et al. (2017) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-16-3193 · Cited by 393
Delker, A., Fendler, W. P., Kratochwil, C., Brunegraf, A., Gosewisch, A., Gildehaus, F. J., Tritschler, S., Stief, C. G., Kopka, K., Haberkorn, U., et al. (2016) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-015-3174-7 · Cited by 322
“Furthermore, S values were corrected for individual organ mass [18, 19].”
MethodEANM Dosimetry Committee guidelines for bone marrow and whole-body dosimetry
Hindorf, C., Glatting, G., Chiesa, C., Lindén, O., & Flux, G. (2010) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-010-1422-4 · Cited by 297
Cho, S. Y., Gage, K. L., Mease, R. C., Senthamizhchelvan, S., Holt, D. P., Jeffrey-Kwanisai, A., Endres, C. J., Dannals, R. F., Sgouros, G., Lodge, M., et al. (2012) · Journal of Nuclear Medicine · doi:10.2967/jnumed.112.104661 · Cited by 279
Chawla, S. C., Federman, N., Zhang, D., Nagata, K., Nuthakki, S., McNitt-Gray, M., & Boechat, M. I. (2010) · Pediatric Radiology · doi:10.1007/s00247-009-1434-z · Cited by 218
“The program has phantom libraries that permit the calculation of doses for individuals of different ages and sizes [12].”
BackgroundFirst-in-Man Evaluation of 2 High-Affinity PSMA-Avid Small Molecules for Imaging Prostate Cancer
Barrett, J. A., Coleman, R. E., Goldsmith, S. J., Vallabhajosula, S., Petry, N. A., Cho, S., Armor, T., Stubbs, J. B., Maresca, K. P., Stabin, M. G., et al. (2013) · Journal of Nuclear Medicine · doi:10.2967/jnumed.112.111203 · Cited by 208
“Organ-Absorbed Radiation Dose Estimates The OLINDA/EXM software was used to estimate absorbed radiation dose to target organs (23,24).”
MethodSelf-citationSchuchardt, C., Zhang, J., Kulkarni, H. R., Chen, X., Müller, D., & Baum, R. P. (2022) · Journal of Nuclear Medicine · doi:10.2967/jnumed.121.262713 · Cited by 187
Wehrmann, C., Senftleben, S., Zachert, C., Müller, D., & Baum, R. P. (2007) · Cancer Biotherapy and Radiopharmaceuticals · doi:10.1089/cbr.2006.325 · Cited by 177
“16,17 To determine the time-activity profile in a specific region, serial planar whole-body scintigra-phies (MEDISO [Medical Imaging Systems, Bu-dapest, Hungary] XRING and spirit DH-V gamma camera; MeGP collimator; peak at 208 keV; 15% energy window; 15 cm/minutes) at different times following an…”
Nephrotoxicity after PRRT with 177Lu-DOTA-octreotate
Bergsma, H., Konijnenberg, M. W., van der Zwan, W. A., Kam, B. L. R., Teunissen, J. J. M., Kooij, P. P., Mauff, K. A. L., Krenning, E. P., & Kwekkeboom, D. J. (2016) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-016-3382-9 · Cited by 177
“The (177)Lu S-values were taken from the RADAR website [15]: for adult male kidneys (with a mass of 299 g) the S-value is 0.”
MethodMinimizing and Communicating Radiation Risk in Pediatric Nuclear Medicine
Fahey, F. H., Treves, S. T., & Adelstein, S. J. (2011) · Journal of Nuclear Medicine · doi:10.2967/jnumed.109.069609 · Cited by 165
“Tables of S values for patients of different ages can be used to estimate the radiation dose to children (15,16).”
MethodJohansen, A., Holm, S., Dall, B., Keller, S., Kristensen, J. L., Knudsen, G. M., & Hansen, H. D. (2019) · EJNMMI Research · doi:10.1186/s13550-019-0527-4 · Cited by 10
Metadata
- Authors
- Stabin, M. G., & Siegel, J. A.
- Venue
- Health Physics
- Published
- 2003-09
- Volume
- 85
- Issue
- 3
- Pages
- 294-310
- ISSN
- 0017-9078 (ISSN-L)
- OpenAlex
- W1997945349
- Cited by
- 313
- References
- 6
- FWCI
- 6.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.