The DOI matches its Crossref record.
Precision and Accuracy of Bone Mineral Determination by Direct Photon Absorptiometry
Abstract
Bone mineral was determined using a radiologic absorptiometric method. The attenuation of a low-energy beam from a well-collimated radionuclide source (125I or 241Am) was measured using a collimated scintillation detectorpulse height analyzer system. The absorption of the photon beam by bone, as shown by this scanning method, was highly correlated with the weight of standard sections on excised bones (r = 0.97 to 0.99). Even scans on tissue covered cadaver forearms were highly correlated (r = 0.96) with the weight of underlying bone components and single scans on human ulnae were highly correlated (r= 0.96) with total ulna weight. The precision (2%) and accuracy (4 to 7%error) were the highest ever demonstrated for a radiologic method of bone determination and the large inaccuracies (more than 20 to 30% error) of older methods, which used photodensitometry of radiographs, were eliminated by the present method. Improved techniques allow even higher precision (1 to 2%) and accuracy (2 to 4%); therefore, the radionuclide absorption method is potentially useful for diagnostic, clinical and normative evaluation of appendicular skeletal mineralization where older photodensitometric methods cannot be used.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Dual-energy X-ray absorptiometry body composition model: review of physical concepts
Pietrobelli, A., Formica, C., Wang, Z., & Heymsfield, S. B. (1996) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1996.271.6.e941 · Cited by 594
Osteoporosis in Men with Idiopathic Hypogonadotropic Hypogonadism
FINKELSTEIN, J. S., KLIBANSKI, A., NEER, R. M., GREENSPAN, S. L., ROSENTHAL, D. I., & CROWLEY, W. F. (1987) · Annals of Internal Medicine · doi:10.7326/0003-4819-106-3- · Cited by 408
Long-term calcitonin therapy in postmenopausal osteoporosis
Gruber, H. E., Ivey, J. L., Baylink, D. J., Matthews, M., Nelp, W. B., Sisom, K., & Chesnut, C. H. (1984) · Metabolism · doi:10.1016/0026-0495(84)90187-2 · Cited by 329
Risk factors for postmenopausal osteoporosis
Aloia, J. F., Cohn, S. H., Vaswani, A., Yeh, J. K., Yuen, K., & Ellis, K. (1985) · The American Journal of Medicine · doi:10.1016/0002-9343(85)90468-1 · Cited by 313
Variations in strength and structure of cancellous bone at the knee
Behrens, J. C., Walker, P. S., & Shoji, H. (1974) · Journal of Biomechanics · doi:10.1016/0021-9290(74)90010-4 · Cited by 171
Metadata
- Authors
- Cameron, J. R., Mazess, R. B., & Sorenson, J. A.
- Venue
- Investigative Radiology
- Published
- 1968-05
- Volume
- 3
- Issue
- 3
- Pages
- 141-150
- ISSN
- 0020-9996 (ISSN-L)
- OpenAlex
- W2047672134
- Cited by
- 369
- References
- 0
- FWCI
- 16.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Precision and Accuracy of Bone Mineral Determination by Direct Photon Absorptiometry. https://app.cochat.ai/papers/10.1097/00004424-196805000-00001
- The paper
- Cameron, J. R., Mazess, R. B., & Sorenson, J. A. (1968). Precision and Accuracy of Bone Mineral Determination by Direct Photon Absorptiometry. Investigative Radiology. https://doi.org/10.1097/00004424-196805000-00001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.