Comparison of Bilateral-Subtraction and Single-Image Processing Techniques in the Computerized Detection of Mammographic Masses
The DOI matches its Crossref record.
Abstract
RATIONALE AND OBJECTIVES: Identification of regions as possible masses on digitized screen film mammograms is an important initial step in the computerized detection of breast carcinomas. Possible masses may be initially extracted using criteria based on optical densities, geometric patterns, and asymmetries between corresponding locations in right and left mammograms. In this study, the usefulness of information arising from mammographic asymmetries for the identification of mass lesions is investigated. METHODS: Two techniques are investigated--a nonlinear bilateral-subtraction technique based on image pairs and a local gray-level thresholding technique based on single images. Detection performances obtained with the two techniques in combination with various feature-analysis techniques are evaluated using 154 pairs of mammograms and compared using free-response receiver operating characteristic (FROC) analysis. RESULTS: The nonlinear bilateral-subtraction technique performed better than the local gray-level thresholding technique. CONCLUSION: The incorporation of asymmetric information appears to be useful for computerized identification of possible masses on mammograms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Computer-aided diagnosis in medical imaging: historical review, current status and future potential
Doi, K. (2007) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2007.02.002 · Cited by 1,855
“[67] Yin FF, Giger ML, Vyborny CJ, Doi K, Schmidt RA.”
BackgroundMethodSelf-citationPisano, E. D., Zong, S., Hemminger, B. M., DeLuca, M., Johnston, R. E., Muller, K., Braeuning, M. P., & Pizer, S. M. (1998) · Journal of Digital Imaging · doi:10.1007/bf03178082 · Cited by 766
The Potential of Radiomic-Based Phenotyping in Precision Medicine: A Review
Aerts, H. J. W. L. (2016) · JAMA Oncology · doi:10.1001/jamaoncol.2016.2631 · Cited by 669
Approaches for automated detection and classification of masses in mammograms
Cheng, H. D., Shi, X. J., Min, R., Hu, L. M., Cai, X. P., & Du, H. N. (2006) · Pattern Recognition · doi:10.1016/j.patcog.2005.07.006 · Cited by 538
A review of automatic mass detection and segmentation in mammographic images
Oliver, A., Freixenet, J., Martí, J., Pérez, E., Pont, J., Denton, E. R. E., & Zwiggelaar, R. (2010) · Medical Image Analysis · doi:10.1016/j.media.2009.12.005 · Cited by 398
Metadata
- Authors
- YIN, F.-F., GIGER, M. L., VYBORNY, C. J., DOI, K., & SCHMIDT, R. A.
- Venue
- INVESTIGATIVE RADIOLOGY
- Published
- 1993-06
- Volume
- 28
- Issue
- 6
- Pages
- 473-481
- ISSN
- 0020-9996 (ISSN-L)
- OpenAlex
- W2026817651
- Cited by
- 94
- References
- 0
- FWCI
- 7.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of Bilateral-Subtraction and Single-Image Processing Techniques in the Computerized Detection of Mammographic Masses. https://app.cochat.ai/papers/10.1097/00004424-199306000-00001
- The paper
- YIN, F.-F., GIGER, M. L., VYBORNY, C. J., DOI, K., & SCHMIDT, R. A. (1993). Comparison of Bilateral-Subtraction and Single-Image Processing Techniques in the Computerized Detection of Mammographic Masses. INVESTIGATIVE RADIOLOGY. https://doi.org/10.1097/00004424-199306000-00001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.