CoChat

3D Versus 2D Ultrasound: Accuracy of Volume Measurement in Human Cadaver Kidneys

PARTIK, BERNHARD L., STADLER, ALFRED, SCHAMP, STEPHAN, KOLLER, ANKE, VORACEK, MARTIN, HEINZ, GERTRAUD, HELBICH, THOMAS H. · 2002 · Investigative Radiology
Cited by 76

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Partik B, Stadler A, Schamp S, et al. 3D versus 2D ultrasound. Accuracy of volume measurement in human cadaver kidneys. Invest Radiol 2002;37:489–495. Rationale and Objectives. Comparison of the accuracy of 3D and 2D ultrasound in assessing the volume of human cadaver kidneys. Materials and Methods. Before autopsy the volume of 22 kidneys was assessed from a 3D data set after manually tracing organ contours (3D volumetry) and by applying a 3D ellipsoid formula both on a 3D data set and 2D images. Measurements by water-displacement served as the gold standard. Results. 3D volumetry showed a mean absolute deviation of 31 mL (18.5%) compared with the mean gold standard measurement (168 mL), yielding a concordance correlation (Lin’s ρc) of 0.71. Calculation based on the ellipsoid formula revealed a mean absolute deviation of 37 mL (22.0%) when applied on the 3D data set (ρc = 0.65) and of 42 mL (25.0%) when applied on 2D images (ρc = 0.61), respectively. Conclusions. 3D volumetry showed a satisfactory concordance correlation and is superior to volume calculation based on the ellipsoid formula either applied to a 3D data set or to conventional 2D images in assessing the volume of human cadaver kidneys.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00004424-200209000-00003

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 76

Metadata

Authors
PARTIK, B. L., STADLER, A., SCHAMP, S., KOLLER, A., VORACEK, M., HEINZ, G., & HELBICH, T. H.
Venue
Investigative Radiology
Published
2002-09
Volume
37
Issue
9
Pages
489-495
ISSN
0020-9996 (ISSN-L)
OpenAlex
W4231377289
Cited by
76
References
2
FWCI
0.53
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: 3D Versus 2D Ultrasound: Accuracy of Volume Measurement in Human Cadaver Kidneys. https://app.cochat.ai/papers/10.1097/00004424-200209000-00003
The paper
PARTIK, B. L., STADLER, A., SCHAMP, S., KOLLER, A., VORACEK, M., HEINZ, G., & HELBICH, T. H. (2002). 3D Versus 2D Ultrasound: Accuracy of Volume Measurement in Human Cadaver Kidneys. Investigative Radiology. https://doi.org/10.1097/00004424-200209000-00003

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.