Methods of Analysis of Nonstationary EEGs, with Emphasis on Segmentation Techniques: A Comparative Review
The DOI matches its Crossref record.
Abstract
Methods for analysis of nonstationary EEGs, that is, EEGs whose patterns undergo changes with time (e.g., alpha blocking, paroxysmal slow waves, onset of drowsiness/sleep, but excluding spikes/sharp waves) are reviewed. The concepts of stationarity and nonstationarity, and general techniques for their evaluation, are discussed. Simpler methods for monitoring for nonstationarity include running determinations of average amplitude and average period or interval. Piecewise stationary analysis includes characterization, by spectra obtained by fast Fourier transform or by autoregressive modeling, of sections of EEGs preselected to be stationary. In Kalman filtering, the autoregressive model itself becomes time-varying. Segmentation of the EEG into stationary lengths can be carried out on a fixed-interval basis (i.e., of successive, e.g., 1-s intervals), with clustering (grouping) or classification according to the features (e.g., spectra) of each interval, and concatenation of adjacent similar intervals. Alternatively, in adaptive (variable-interval) segmentation, the EEG is continuously monitored automatically for any significant departure from stationarity, and segment boundaries are placed accordingly. A number of applications of the various methods are included, with examples of succinct summary displays. Problems and prospects are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Meditation states and traits: EEG, ERP, and neuroimaging studies.
Cahn, B. R., & Polich, J. (2006) · Psychological Bulletin · doi:10.1037/0033-2909.132.2.180 · Cited by 1,734
Mormann, F., Lehnertz, K., David, P., & E. Elger, C. (2000) · Physica D: Nonlinear Phenomena · doi:10.1016/s0167-2789(00)00087-7 · Cited by 1,286
EEG alpha map series: brain micro-states by space-oriented adaptive segmentation
Lehmann, D., Ozaki, H., & Pal, I. (1987) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(87)90025-3 · Cited by 913
A systematic review of neurobiological and clinical features of mindfulness meditations
Chiesa, A., & Serretti, A. (2010) · Psychological Medicine · doi:10.1017/s0033291709991747 · Cited by 749
Epileptic seizures are preceded by a decrease in synchronization
Mormann, F., Kreuz, T., Andrzejak, R. G., David, P., Lehnertz, K., & Elger, C. E. (2003) · Epilepsy Research · doi:10.1016/s0920-1211(03)00002-0 · Cited by 456
Lehnertz, K., & Elger, C. E. (1995) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(95)00071-6 · Cited by 325
A review of parametric modelling techniques for EEG analysis
Pardey, J., Roberts, S., & Tarassenko, L. (1996) · Medical Engineering & Physics · doi:10.1016/1350-4533(95)00024-0 · Cited by 286
Kaplan, A. Y., Fingelkurts, A. A., Fingelkurts, A. A., Borisov, S. V., & Darkhovsky, B. S. (2005) · Signal Processing · doi:10.1016/j.sigpro.2005.07.010 · Cited by 276
Signal processing techniques applied to human sleep EEG signals—A review
Motamedi-Fakhr, S., Moshrefi-Torbati, M., Hill, M., Hill, C. M., & White, P. R. (2014) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2013.12.003 · Cited by 263
Dynamics of brain electrical activity
Rapp, P. E., Bashore, T. R., Martinerie, J. M., Albano, A. M., Zimmerman, I. D., & Mees, A. I. (1989) · Brain Topography · doi:10.1007/bf01128848 · Cited by 248
Adaptive segmentation of spontaneous EEG map series into spatially defined microstates
Wackermann, J., Lehmann, D., Michel, C. M., & Strik, W. K. (1993) · International Journal of Psychophysiology · doi:10.1016/0167-8760(93)90041-m · Cited by 215
Mormann, F., Andrzejak, R. G., Kreuz, T., Rieke, C., David, P., Elger, C. E., & Lehnertz, K. (2003) · Physical Review E · doi:10.1103/physreve.67.021912 · Cited by 203
Epileptic seizure detection in EEGs signals using a fast weighted horizontal visibility algorithm
Zhu, G., Li, Y., & Wen, P. (. (2014) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2014.04.001 · Cited by 166
“In fact, Barlow [36] sugested that better segment period is 1 s.”
Rethinking Sleep Analysis: Comment on the AASM Manual for the Scoring of Sleep and Associated Events
Schulz, H. (2008) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.27124 · Cited by 165
Chaotic time series analyses of epileptic seizures
Frank, G. W., Lookman, T., Nerenberg, M. A. H., Essex, C., Lemieux, J., & Blume, W. (1990) · Physica D: Nonlinear Phenomena · doi:10.1016/0167-2789(90)90103-v · Cited by 163
Metadata
- Authors
- Barlow, J. S.
- Venue
- Journal of Clinical Neurophysiology
- Published
- 1985-07
- Volume
- 2
- Issue
- 3
- Pages
- 267-304
- ISSN
- 0736-0258 (ISSN-L)
- OpenAlex
- W1993230712
- Cited by
- 158
- References
- 0
- FWCI
- 1.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.