Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 247

The DOI matches its Crossref record.

Quantitative EEG: I. Techniques and Problems of Frequency Analysis and Topographic Mapping

Nuwer, Marc R. · 1988 · Journal of Clinical Neurophysiology

Abstract

Quantitative EEG techniques include frequency analysis (spectral analysis), significance probability mapping, and other analytic techniques. Each can be done on spontaneous EEG in various states or in conjunction with sensory stimulation. Several types of displays are available, including topographic mapping of scalp electrical activity. Assessment of normality in these records must take into account age, gender, state of alertness, medications, and other factors. Substantial statistical issues are critical in these assessments and must be thoroughly understood by all users. Other problems can easily mislead the interpretations of these tests, sometimes in subtle ways. References are often active. Traditional EEG artifacts can appear in surprising ways, and new artifacts can be caused by computer processing and display format. Important technical choices must be made in recording quantitative EEG, and the correct choices are not clearly known. These choices include references, number of channels, epoch length, number of epochs acquired, and artifact rejection criteria. This review summarizes a variety of the techniques commonly used. Advantages of particular methods are contrasted. Problems with these techniques are discussed at length, with emphasis on the difficulties and choices facing users of typical commercial quantitative EEG machines. As quantitative EEG techniques come into some clinical use, issues of nomenclature, technique, normality, and problems will become widely understood. For now, clinicians should respect the problems inherent in these techniques. Quantitative EEG tests should only be interpreted along with the traditional paper EEG tracing that represents the raw data on which the quantitative analysis was performed. A thorough familiarity with traditional EEG is a prerequisite to understanding the meaning of the quantitative EEG results.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00004691-198801000-00001

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 247

Metadata

Authors
Nuwer, M. R.
Venue
Journal of Clinical Neurophysiology
Published
1988-01
Volume
5
Issue
1
Pages
1-44
ISSN
0736-0258 (ISSN-L)
OpenAlex
W4297900197
Cited by
247
References
0
FWCI
6.78
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Quantitative EEG: I. Techniques and Problems of Frequency Analysis and Topographic Mapping. https://app.cochat.ai/papers/10.1097/00004691-198801000-00001
The paper
Nuwer, M. R. (1988). Quantitative EEG: I. Techniques and Problems of Frequency Analysis and Topographic Mapping. Journal of Clinical Neurophysiology. https://doi.org/10.1097/00004691-198801000-00001

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.