Cardiac Artifacts in Magnetoencephalogram
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
We studied cardiac contamination of magnetoencephalographic signals in eight healthy volunteers. The signals were recorded in a magnetically shielded room while the subject was sitting under a whole-scalp neuromagnetometer and were averaged time-locked to the R wave of the electrocardiogram. The maximum amplitude of the cardiac artifact varied between the subjects and was on average 130 fT/cm. The number of significantly contaminated channels was higher over the left than the right hemisphere. The electric and magnetic signals varied over time in the same way, implying that the artifacts are generated by cardiac currents, without any significant contribution from blood-flow-related pulsations or body movements. These artifacts may have a considerable effect on unaveraged data, i.e., recordings of spontaneous brain activity, and thus should be taken into account in the analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684
Self-citation
Cited by
Signal-space projection method for separating MEG or EEG into components
Uusitalo, M. A., & Ilmoniemi, R. J. (1997) · Medical & Biological Engineering & Computing · doi:10.1007/bf02534144 · Cited by 913
Ille, N., Berg, P., & Scherg, M. (2002) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-200203000-00002 · Cited by 741
Visceral Signals Shape Brain Dynamics and Cognition
Azzalini, D., Rebollo, I., & Tallon-Baudry, C. (2019) · Trends in Cognitive Sciences · doi:10.1016/j.tics.2019.03.007 · Cited by 409
MEG: An Introduction to Methods
(2010) · Oxford University Press eBooks · doi:10.1093/acprof:oso/9780195307238.001.0001 · Cited by 408
MEG/EEG sources of the 170-ms response to faces are co-localized in the fusiform gyrus
Deffke, I., Sander, T., Heidenreich, J., Sommer, W., Curio, G., Trahms, L., & Lueschow, A. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.01.034 · Cited by 255
Metadata
- Authors
- Jousm??ki, V., & Hari, R.
- Venue
- Journal of Clinical Neurophysiology
- Published
- 1996-03
- Volume
- 13
- Issue
- 2
- Pages
- 172-176
- ISSN
- 0736-0258 (ISSN-L)
- OpenAlex
- W2069586676
- Cited by
- 59
- References
- 1
- FWCI
- 0.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cardiac Artifacts in Magnetoencephalogram. https://app.cochat.ai/papers/10.1097/00004691-199603000-00008
- The paper
- Jousm??ki, V., & Hari, R. (1996). Cardiac Artifacts in Magnetoencephalogram. Journal of Clinical Neurophysiology. https://doi.org/10.1097/00004691-199603000-00008
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.