The DOI matches its Crossref record.
A Method for Correcting Bone Induced Artifacts in Computed Tomography Scanners
Abstract
A method that corrects for artifacts in X-ray transmission scanners created by the alteration of the energy spectrum by bone is described. The method involves two reconstructions of the pictures: the first establishes the approximate distribution of bone and the second enables the artifacts to be eliminated. The first reconstruction is needed to establish the total amount of bone along each ray. Assuming that the X-ray energy spectrum is known, it is shown how the line integrals can be corrected. The method was tested on several mathematical phantoms as well as on human head data. The nonlinear nature of the spectral artifacts is shown to produce streaks in certain phantoms.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“the large extracranial metal components and dental cement of the implant can cause beam hardening that can appear as cupping, streaks, dark bands or flare in the µCT38–40.”
From Oxytocin neurons enable social transmission of maternal behaviour (2021) · cites this paper as [40]
Citations
Cited by
Sorted by citations
Items 201–281 of 281
Yang, Q., Wu, M., Maier, A., et al. (2014) · Informatik aktuell · doi:10.1007/978-3-642-54111-7_13 · Cited by 4
Calibration-free 3D ray-tracing beam hardening correction in computed tomography
Seracini, M., Bettuzzi, M., Brancaccio, R., et al. (2024) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2024.169226 · Cited by 4
Vessel-targeted compensation of deformable motion in interventional cone-beam CT
Lu, A., Huang, H., Hu, Y., Zbijewski, W. B., Unberath, M., Siewerdsen, J. H., Weiss, C. R., & Sisniega, A. (2024) · Medical Image Analysis · doi:10.1016/j.media.2024.103254 · Cited by 4
Beam Hardening Correction for Image-Domain Material Decomposition in Photon-Counting CT
Fan, T., Qin, W., Zhang, Z.-L., et al. (2025) · IEEE Transactions on Radiation and Plasma Medical Sciences · doi:10.1109/trpms.2025.3540212 · Cited by 4
“To date, numerous beam hardening correction (BHC) methods have been proposed [13], [14], [15], [16], [17].”
Zangeneh, F. A., Almeida, G. G., Bensler, S., et al. (2025) · Academic Radiology · doi:10.1016/j.acra.2025.05.054 · Cited by 4
A Review of Current Knowledge for X-ray Energy in CT: Practical Guide for CT Technologist
Hoyoshi, K., Ohmura, T., Kayano, S., et al. (2022) · Japanese Journal of Radiological Technology · doi:10.6009/jjrt.2022-1238 · Cited by 4
Jacobson, M. W., Lehmann, M., Huber, P., et al. (2021) · Physics in Medicine and Biology · doi:10.1088/1361-6560/abddd2 · Cited by 4
A study of the anatomical variations of the carotid arterial tree in Equidae
Hayah, N. (2012) · Enlighten: Theses (The University of Glasgow) · Cited by 4
High resolution CT spinal scanning with ACTA 0200 FS
Ruggiero, R., Capece, W., Vecchio, E. D., et al. (1981) · Neuroradiology · doi:10.1007/bf00344606 · Cited by 4
“Recently Pfizer made available new, more sophisticated software, which allows bone correction [ 17 ].”
MethodZhao, W. P., Li, D., Niu, K., et al. (2018) · arXiv (Cornell University) · doi:10.48550/arxiv.1812.02365 · Cited by 4
“The interests in correction of beam hardening artifacts induced by multi-material objects (especially bone) began since early days of CT imaging [34], [35], [31], [36], [33], [37], [38], [32], [18], [39], [40], [41], [42], [23], however, high order beam hardening artifacts are still present in CT images acquired on mo…”
BackgroundMethodXu, J., Sisniega, A., Zbijewski, W. B., et al. (2016) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2216544 · Cited by 3
“38(10), 5612, American Association of Physicists in Medicine (2011).”
BackgroundCT metal artifacts simulation under x-ray total absorption
Shutov, M., Gilmanov, M., Dmitry, P., et al. (2024) · doi:10.1117/12.3023491 · Cited by 3
“In the scope of current work the main focus will be on the artifacts, arising due to the presence of strongly absorbing inclusions (such as metals) in the object under study – metal-like artifacts (MA) [15].”
BackgroundSanderson, D., Martínez, C., Fessler, J. A., et al. (2024) · Medical Physics · doi:10.1002/mp.17239 · Cited by 3
Basis Vector Model Method for Proton Stopping Power Estimation using Dual-Energy Computed Tomography
Zhang, S. (2019) · Open Scholarship Institutional Repository (Washington University in St. Louis) · doi:10.7936/1j70-h466 · Cited by 3
An Application Approach to Kalman Filter and CT Scanners for Soil Science
Laia, M. A. D. M., & Almeida, P. E. M. (2011) · InTech eBooks · doi:10.5772/31030 · Cited by 3
“…as polychromatic sources (non-ideal or monochromatic), caused by the following effects: beam hardening, aliasing, different materials in the same voxel (partial volume), displacement of the sample or of the equipment (Duerinckx & Macocski, 1978; Joseph & Spital, 1978; Ibbott, 1980; Granato, 1998).”
BackgroundA new method for cupping and scatter precorrection for flat detector CT
Grimmer, R., Maaß, C., & Kachelrieß, M. (2009) · 2006 IEEE Nuclear Science Symposium Conference Record · doi:10.1109/nssmic.2009.5401805 · Cited by 3
“In our case this would be the energy dependence of water and the correction that is applied in all clinical CT scanners is known as water precorrection [6].”
BackgroundSegmentation-free quasi-Newton method for polyenergetic CT reconstruction
Humphries, T., & Faidani, A. (2014) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.2014.7430945 · Cited by 3
Empirical cupping correction for CT scanners with tube voltage modulation (ECCU)
Ritschl, L., Bergner, F., Fleischmann, C., et al. (2009) · 2006 IEEE Nuclear Science Symposium Conference Record · doi:10.1109/nssmic.2009.5401946 · Cited by 3
“Therefore dedicated first, second or higher order correction algorithms have been designed [1], [2], [3], [4], [5], [ 6 ], [7], [8], [9], [10], [11], [12], [13], [14], [15], [16], 2009 IEEE Nuclear Science Symposium Conference Record M13-381”
BackgroundMethodTang, S., Huang, T., Qiao, Z., et al. (2022) · Journal of X-Ray Science and Technology · doi:10.3233/xst-221176 · Cited by 3
“…the streaks artifacts caused by bone like substances at the same time, but it is usually necessary to use cumbersome physical experiments to determine the scale factor, (cid:2) 0 , in advance, which is subsequently used to convert the reconstruction value of bone tissue into bulk density [6, 7].”
Jørgensen, J. S., Papoutsellis, E., Murgatroyd, L., et al. (2023) · Applied Mathematics for Modern Challenges · doi:10.3934/ammc.2023011 · Cited by 3
Reconstruction of CT images from sparse-view polyenergetic data using total variation minimization
Humphries, T., & Faridani, A. (2015) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.2015.7582013 · Cited by 2
“This approach consists of applying a well-known classical technique for beam hardening correction proposed by Joseph and Spital [11], followed by TV minimization applied as a post-processing step.”
MethodQuantitative Electron Density CT Imaging for Radiotherapy Planning
Mason, J. H., Perelli, A., Nailon, W. H., et al. (2017) · Communications in computer and information science · doi:10.1007/978-3-319-60964-5_26 · Cited by 2
A kV–MV approach to CBCT metal artifact reduction using multi-layer MV-CBCT
Jacobson, M. W., Harris, T. C., Myronakis, M. E., et al. (2024) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ad1cfb · Cited by 2
Feasibility of bone marrow edema detection using dual‐energy cone‐beam computed tomography
Liu, S. Z., Herbst, M., Schaefer, J., et al. (2024) · Medical Physics · doi:10.1002/mp.16962 · Cited by 2
Hosoo, H., Ito, Y., Hirata, K., et al. (2024) · American Journal of Neuroradiology · doi:10.3174/ajnr.a8472 · Cited by 2
Complete scheme for beam hardening correction in small animal computed tomography
de Molina, C., Sisniega, A., Vaquero, J. J., et al. (2012) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.2012.6551880 · Cited by 2
A complete scheme of empirical beam hardening correction using Grangeat consistency condition
Abdurahman, S., Frysch, R., Bismark, R., et al. (2018) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.2018.8824734 · Cited by 2
“If the object is made up of different materials with low and high attenuation coefficients, the streak and spill-over (higher order) artifacts will also be visible [2][3].”
BackgroundSingle Material Beam Hardening Correction in CT Using an Analytical Energy Response Model
Haase, V., Hähn, K., Schöndube, H., et al. (2020) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nss/mic42677.2020.9507774 · Cited by 2
Rührnschopf, E., Schwierz, G., & Eschenbacher, H. (1981) · Lecture notes in medical informatics · doi:10.1007/978-3-642-93157-4_20 · Cited by 2
Ciassification of Artifacts in X-Ray Cr Images Due to Nonlinear Shadows
Duerinckx, A. J., & Macovski, A. (1979) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.1979.4330548 · Cited by 2
Evaluation of the effects of titanium induced CT artifacts on biomechanical models generation
Zannoni, C., Viceconti, M., Pierotti, L., et al. (2002) · Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.1997.757095 · Cited by 2
Song, C., Li, T., Li, H., et al. (2024) · Applied Sciences · doi:10.3390/app14209221 · Cited by 1
Study on the impact of bowtie filter on photon-counting CT imaging
Zhang, X., Xie, J., Su, T., et al. (2024) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ad8858 · Cited by 1
“These techniques can be categorized into four types: linearization methods (Brooks and Di Chiro 1976, McDavid et al 1977, Joseph and Spital 1978, Rüegsegger et al 1978, Herman 1979, Nalcioglu and Lou 1979, Herman and Trivedi 1983, Robertson and Huang 1986, Meagher et al 1990, Kyriakou et al 2010),…”
Piol, A., Sanderson, D., Cerro, C. F. D., et al. (2024) · Sensors · doi:10.3390/s24216782 · Cited by 1
“To correct both cupping and dark bands, some works model the beam-hardening effect using knowledge about the X-ray spectrum together with an estimation of the tissue thicknesses traversed [3,4].”
MethodCalibration Method for Reducing Ring Artifacts in Energy Bin Images for Photon-Counting CT
Lee, D., Zhan, X., Tai, W.-H., et al. (2025) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2025.3603880 · Cited by 1
“…calibration approaches that aim to achieve additional objectives (often involving multiple materials), such as beam-hardening correction (BHC) [25], [26], [27] or material decomposition (MD) [28], [29], [30], [31], [32], also typically correct for pixel-to-pixel variations as part of the…”
Application of run-length coding in reprojection
Fatemi, M., & Kelarestaghi, M. (2003) · doi:10.1109/nssmic.1992.301046 · Cited by 1
Jang, K. E., Lee, J., Sung, Y., et al. (2013) · Medical Physics · doi:10.1118/1.4816945 · Cited by 1
4. Measurement of Projection Data—The Nondiffracting Case
(2001) · Society for Industrial and Applied Mathematics eBooks · doi:10.1137/1.9780898719277.ch4 · Cited by 1
Lin, Y., & Samei, E. (2016) · Journal of medical imaging · doi:10.1117/1.jmi.3.3.033503 · Cited by 1
Empirical beam hardening and ring artifact correction for x‐ray grating interferometry (EBHC‐GI)
Nelson, B., Leng, S., Shanblatt, E. R., et al. (2020) · Medical Physics · doi:10.1002/mp.14672 · Cited by 1
Adaptive beam hardening correction based on projection data consistency condition
Tang, S., Mou, X., Xu, Q., et al. (2010) · doi:10.1109/nssmic.2010.5874199 · Cited by 1
“Adaptive Beam Hardening Correction Here, the H-L consistency condition [4], [9] and bone correction [2] are combined to determine an optimal scaling factor 0 λ by minimizing the following objective function,”
BackgroundMethodAmato, A. C. M., Filho, J. R. P., & Stolf, N. A. G. (2018) · Jornal Vascular Brasileiro · doi:10.1590/1677-5449.006317 · Cited by 1
A practical analysis of scatter-to-primary ratio after beam hardening correction for x-ray CT
Gao, H., Jia, S., & Fu, G. (2019) · SPIE Medical Imaging: Physics of Medical Imaging · doi:10.1117/12.2513266 · Cited by 1
Kachelrieß, M. (2018) · Springer eBooks · doi:10.1007/978-3-662-54801-1_8 · Cited by 1
(2018) · ASM International eBooks · doi:10.31399/asm.hb.v17.a0006456 · Cited by 1
Iterative Ct Reconstruction Using Reprojection
Crawford, C. R., & Lonn, A. H. R. (2005) · doi:10.1109/iembs.1990.691119 · Cited by 1
An Iterative Approach to the Beam Hardening Correction in Cone Beam CT (Proceedings)
Hsieh, J., Molthen, R. C., DAWSON, C. A., et al. (1999) · e-Publications@Marquette (Marquette University) · Cited by 1
Image Quality, Modeling, and Design for High-Performance Cone-Beam CT of the Head
Xu, J. (2016) · Cited by 1
A model-based correction method for beam hardening artefacts in X-ray tomography
de Casteele, E. V., Dyck, D. V., Sijbers, J., et al. (2003) · Cited by 1
Artifacts handling and DBS electrodes localization in the CT/MRI brain images
Motevakel, A. (2013) · KTH Publication Database DiVA (KTH Royal Institute of Technology) · Cited by 1
CT Densitometry in Osteoporosis: The impact on management of the patient
Lampmann, L. E. H., Duursma, S. A., & Ruys, T. (2011) · Medical Entomology and Zoology · Cited by 1
A Method for Correcting Anisotropic Blurs in Magnetic Resonance Images
Ro, D. W., Joseph, P. M., Lewitt, R. M., et al. (1992) · Springer eBooks · doi:10.1007/978-3-642-77888-9_29 · Cited by 1
Self-citationStatistical reconstruction for quantitative CT applications
Elbakri, I. A., Zhang, Y., Chen, L., et al. (2004) · 2006 IEEE Nuclear Science Symposium Conference Record · doi:10.1109/nssmic.2003.1352510
“This approach cannot be perfect in all situations since it only allows one degree of freedom per voxel, but it can produce better results in the single-kVp case than conventional water/bone correction methods [8], [9].”
BackgroundIterative Bone Correction Coefficient Selection Based on the Normalized Bone Index of Images
Li, J. (2006) · 2006 IEEE Nuclear Science Symposium Conference Record · doi:10.1109/nssmic.2005.1596698
Detection and discrimination using x-radiation
Brown, D. G., & Jennings, R. J. (2002) · doi:10.1109/icnn.1997.614683
Beam Hardening Correction for Middle-Energy
Gao, H., Chen, Z., Xing, Y., et al. (2006)
Herman, G. T., & Trivedi, S. (1983)
A Multilevel Domain Decomposition Algorithm for Fast Reprojection of Tomographic
Boag, A., Bresler, Y., & Michielssen, E. (2000)
BEAM HARDENING ARTIFACTS IN COMPUTERIZED TOMOGRAPHY
Spital, R. D. (1979) · Elsevier eBooks · doi:10.1016/b978-0-08-024634-5.50095-9
Self-citationChityala, R. N. (2010) · CRC Press eBooks · doi:10.1201/9781420075250-c26
Bootsma, G. J. (2014) · Library and Archives Canada (Government of Canada)
Interpretation of Periapical Lesions Using Cone Beam Computed Tomography
Estrela, C., Bueno, M. R., & de Alencar, A. H. G. (2012) · doi:10.1002/9781119421689.ch21
A post-processing beam hardening correction method for axial computed tomography
Xue, G., Li, X., & Xu, Z. (2017) · IEEE International Conference on e-Health Networking, Applications and Services (Healthcom) · doi:10.1109/healthcom.2017.8210760
“Nalcioglu[4] and Joseph[5] propose two similar postprocessing method.”
MethodCalibration-free method for beam-hardening compensation: preliminary results
Martínez, C., de Molina, C., Desco, M., et al. (2017) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.2017.8532863
“[4], the authors modeled the corrected data with a second order polynomial dependent on the thickness of traversed bone, also obtained by means of a preliminary reconstruction.”
Deep Monochromatic Metal Artifact Reduction for Computed Tomography
Song, S. S. (2021) · International Conference on Digital Medicine and Image Processing (DMIP) · doi:10.1145/3506651.3506653
“The proposed CNN-based MAR method is inspired by the multimaterial linearization method [45] that uses a polynomial function to transform the polychromatic signal to a corresponding monochromatic one.”
MethodMetal artifact reduction by direct artifact prediction using deep learning in x-ray CT
Yamakawa, K., Goto, T., Kudo, M., et al. (2022) · SPIE Medical Imaging: Physics of Medical Imaging · doi:10.1117/12.2611082
(2009) · Wiley eBooks · doi:10.1002/9780470824023.refs
Zhu, Q., Wang, Y., Zhu, M., et al. (2022) · PubMed · doi:10.12122/j.issn.1673-4254.2022.06.06
Novel method of attenuation-based estimating patient size from single CT localizer radiograph
Lee, C.-L., Han, K., & Cho, M. (2022) · Journal of the Korean Physical Society · doi:10.1007/s40042-022-00520-z
Park, H. S., Jeon, K., & Seo, J. K. (2025) · Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rsta.2024.0045
Statistical Beam-Hardening Correction for Industrial X-ray Computed Tomography
Thierry, R., Flisch, A., Miceli, A., et al. (2010)
Statistical Image Reconstruction and Motion Estimation for Image-Guided Radiotherapy
Long, Y. Q. (2011) · Deep Blue (University of Michigan)
Analysis of beam hardening streaks in tomography
Katsevich, A. I. (2026) · Inverse Problems · doi:10.1088/1361-6420/ae3b6b
“For example, bones and soft tissues/water have very different dependencies of the attenuation coefficient on energy in the interval [ 0 , E mx ] [16, figure 1], [17, 35].”
InfluentialYan, X., He, K., Gao, G., et al. (2026) · Sensors · doi:10.3390/s26082331
“…between carbon and SiC https://doi.org/10.3390/s26082331 phases; conventional X-ray absorption provides only projection attenuation information at a single energy level, which is severely affected by beam-hardening effects [23,24] and thus cannot accurately invert multi-phase component proportions.”
InfluentialChen, K., Xie, S., Cheng, B., et al. (2026) · IEEE International Conference on Acoustics Speech and Signal Processing · doi:10.1109/icassp55912.2026.11463997
Kweon, D. C. (2026) · Spectroscopy Letters · doi:10.1080/00387010.2026.2658777
Mousavi, A., Cassady, V., Marin, G. G., Thapa, S., Prieto, J., Rowland, D. J., Gelb, J., Corsetti, F. A., Scotland, K. B., & Celestian, A. (2026) · Research Square · doi:10.21203/rs.3.rs-9996475/v1
BasisSimulator.jl: Open-source polychromatic CT simulation with a GPU-portable reconstruction stack
Black, D., Khodajou-Chokami, H., & Molloi, S. Y. (2026) · SoftwareX · doi:10.1016/j.softx.2026.102910
Nwokolo, S., Gupta, N., Mitchell, I. T., et al. (2026) · Tomography of Materials and Structures · doi:10.1016/j.tmater.2026.100090
Metadata
- Authors
- Joseph, P. M., & Spital, R. D.
- Affiliations
- NewYork–Presbyterian Hospital (US)
- Venue
- Journal of Computer Assisted Tomography
- Published
- 1978-01
- Volume
- 2
- Issue
- 1
- Pages
- 100-108
- ISSN
- 0363-8715 (ISSN-L)
- OpenAlex
- W2000441297
- Cited by
- 281
- References
- 0
- Citations by year
- 2026: 7 · 2025: 4 · 2024: 10 · 2023: 6 · 2022: 13 · 2021: 6 · 2020: 9 · 2019: 12 · 2018: 17 · 2017: 10 · 2016: 10 · 2015: 9 · 2014: 10 · 2013: 10 · 2012: 13
- FWCI
- 8.33
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Computer Assisted Tomography (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Advanced X-ray and CT Imaging
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiation Dose and Imaging
- Keywords
- bone artifacts, spectral artifacts, X-ray spectra, streak artifacts, head CT, image reconstruction, mathematical phantoms
- MeSH terms
- Bone and Bones, Humans, Mathematics, Models, Structural, Skull, Technology, Radiologic, Tomography, X-Ray Computed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review