Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 227

The DOI matches its Crossref record.

Quantitation in Positron Emission Computed Tomography: 4. Effect of Accidental Coincidences

Hoffman, Edward J., Huang, Sung-Cheng, Phelps, Michael E., Kuhl, David E. · 1981 · Journal of Computer Assisted Tomography

Abstract

Accidental coincidences (ACs) and methods of compensation for ACs were investigated in terms of their effect on quantitation in positron emission computed tomography (ECT). Formulations of basic expressions describing the physical factors, which cause true coincidences or ACs, are presented to provide a framework of contrasting the two phenomena. Correction of image data for attenuation of the annihilation radiation or nonuniformities in detector efficiency is shown to amplify errors caused by the presence of ACs in the data. It was shown that failure to compensate for ACs caused overestimates in measurements of isotope concentrations from image data and that in many cases the overestimate was significant for relatively modest percentages of ACs in the data. Three methods of compensation for ACs were evaluated as to their accuracy and effect on statistical noise in images. It was found that nonuniform detector efficiencies could cause prominent image artifacts if an inadequate method was employed in the determination and subtraction of ACs from image data. The additional statistical noise produced in images by subtraction of ACs from total coincidence data demonstrates the advisability of minimizing AC rates in spite of an ability to adequately measure and compensate for their presence in the data.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00004728-198106000-00015

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 227

Metadata

Authors
Hoffman, E. J., Huang, S.-C., Phelps, M. E., & Kuhl, D. E.
Venue
Journal of Computer Assisted Tomography
Published
1981-06
Volume
5
Issue
3
Pages
391-400
ISSN
0363-8715 (ISSN-L)
OpenAlex
W2045038810
Cited by
227
References
0
FWCI
8.71
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Quantitation in Positron Emission Computed Tomography: 4. Effect of Accidental Coincidences. https://app.cochat.ai/papers/10.1097/00004728-198106000-00015
The paper
Hoffman, E. J., Huang, S.-C., Phelps, M. E., & Kuhl, D. E. (1981). Quantitation in Positron Emission Computed Tomography: 4. Effect of Accidental Coincidences. Journal of Computer Assisted Tomography. https://doi.org/10.1097/00004728-198106000-00015

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.