The DOI matches its Crossref record.
A Computerized System for the Elastic Matching of Deformed Radiographic Images to Idealized Atlas Images
Abstract
A system of computer programs is described which, for the first time, is able to use computerized tomographic data to automatically locate, measure, and describe anatomical structures of interest with accuracy and consistency. Input to the system consists of any digitized radiographic data. Computer assisted tomographic (CAT) scans of the head were used in this first implementation. Using these data and a predefined atlas picture representing an idealized view of the average normal image, an individualized atlas was created. From the individualized atlas, structure size, density, location displacement, and distortion may be calculated. The individualized atlas created using high resolution data, such as the CAT scan, may then be directly superimposed on pictures obtained using lower resolution modalities, such as positron emission tomographic scan images. This allows the precise location of structures poorly visualized by the secondary imaging modality. This system is capable of using either two- or three-dimensional data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Fischl, B., Salat, D. H., Busa, E., Albert, M., Dieterich, M., Haselgrove, C., van der Kouwe, A., Killiany, R., Kennedy, D., Klaveness, S., et al. (2002) · Neuron · doi:10.1016/s0896-6273(02)00569-x · Cited by 8,610
Principal warps: thin-plate splines and the decomposition of deformations
Bookstein, F. L. (1989) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.24792 · Cited by 4,913
A survey of medical image registration
Maintz, J. B. A., & Viergever, M. A. (1998) · Medical Image Analysis · doi:10.1016/s1361-8415(01)80026-8 · Cited by 3,327
Construction of a 3D probabilistic atlas of human cortical structures
Shattuck, D. W., Mirza, M., Adisetiyo, V., Hojatkashani, C., Salamon, G., Narr, K. L., Poldrack, R. A., Bilder, R. M., & Toga, A. W. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2007.09.031 · Cited by 1,203
HAMMER: hierarchical attribute matching mechanism for elastic registration
Shen, D., & Davatzikos, C. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.803111 · Cited by 1,083
Metadata
- Authors
- Bajcsy, R., Lieberson, R., & Reivich, M.
- Venue
- Journal of Computer Assisted Tomography
- Published
- 1983-08
- Volume
- 7
- Issue
- 4
- Pages
- 618-625
- ISSN
- 0363-8715 (ISSN-L)
- OpenAlex
- W1979966786
- Cited by
- 258
- References
- 0
- FWCI
- 6.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Computerized System for the Elastic Matching of Deformed Radiographic Images to Idealized Atlas Images. https://app.cochat.ai/papers/10.1097/00004728-198308000-00008
- The paper
- Bajcsy, R., Lieberson, R., & Reivich, M. (1983). A Computerized System for the Elastic Matching of Deformed Radiographic Images to Idealized Atlas Images. Journal of Computer Assisted Tomography. https://doi.org/10.1097/00004728-198308000-00008
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.