CoChat
Cited by 132

The DOI matches its Crossref record.

Performance Study of the PC-384 Positron Camera System for Emission Tomography of the Brain

Litton, J., Bergstrom, M., Eriksson, L., Bohm, C., Blomqvist, G., Kesselberg, M. · 1984 · Journal of Computer Assisted Tomography

Abstract

A positron camera system PC-384 has been designed and built for quantitative positron emission computed tomography of the brain. This head scanner consists of 384 bismuth germanate oxide scintillation detectors with a crystal packing fraction of 80%. The entire detector assembly rotates around a small circle (wobble) to achieve the necessary ray sampling. Seven simultaneous images are produced with four detector rings. Performances of the system are discussed and clarified based on experimental data.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00004728-198402000-00016

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 132

Metadata

Authors
Litton, J., Bergstrom, M., Eriksson, L., Bohm, C., Blomqvist, G., & Kesselberg, M.
Venue
Journal of Computer Assisted Tomography
Published
1984-02
Volume
8
Issue
1
Pages
74-87
ISSN
0363-8715 (ISSN-L)
OpenAlex
W2057132504
Cited by
132
References
0
FWCI
12.01
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Performance Study of the PC-384 Positron Camera System for Emission Tomography of the Brain. https://app.cochat.ai/papers/10.1097/00004728-198402000-00016
The paper
Litton, J., Bergstrom, M., Eriksson, L., Bohm, C., Blomqvist, G., & Kesselberg, M. (1984). Performance Study of the PC-384 Positron Camera System for Emission Tomography of the Brain. Journal of Computer Assisted Tomography. https://doi.org/10.1097/00004728-198402000-00016

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.