Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 249

The DOI matches its Crossref record.

Imaging Opiate Receptors in the Human Brain by Positron Tomography

Frost, J. James, Wagner, Henry N., Dannals, Robert F., Ravert, Hayden T., Links, Jonathan M., Wilson, Alan A., Burns, H. Donald, Wong, Dean F., McPherson, Robert W., Rosenbaum, Arthur E., Kuhar, Michael J., Snyder, Solomon H. · 1985 · Journal of Computer Assisted Tomography

Abstract

Carfentanil is a potent, synthetic opiate that binds to mu opiate receptors with very high affinity (KI = 0.051 nM, 37 degrees C). In rat brain, carfentanil is 90 and 250 times more selective for mu opiate receptors compared with delta and kappa opiate receptors, respectively. Carbon-11-carfentanil was synthesized by reacting [11C]methyliodide with the carboxylic acid precursor of carfentanil. Carbon-11-carfentanil was injected intravenously in man and a baboon and the distribution of the radioactivity in the brain was monitored using positron emission tomography. High concentrations of radioactivity were observed in the basal ganglia and thalamus, intermediate concentrations in the frontal and parietal cerebral cortex, and low concentrations in the cerebellum and occipital cortex; this distribution corresponds to the known regional density of opiate receptors measured using in vitro techniques. This heterogeneous distribution could be abolished by pretreatment with naloxone (1 mg/kg), an opiate antagonist. The percent inhibition of binding by naloxone is approximately 90% in the caudate nucleus and medial thalamus for the period 30-60 min after injection; therefore, this method is associated with a high level of specific binding to opiate receptors compared with nonspecific binding sites. The ability to measure opiate receptors in vivo in man makes it possible to study a variety of neurologic and psychiatric disorders in which opiate receptors are thought to be abnormal and to study physiologic role of opiate receptors in the central nervous system.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00004728-198503000-00001

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 249

Metadata

Authors
Frost, J. J., Wagner, H. N., Dannals, R. F., Ravert, H. T., Links, J. M., Wilson, A. A., Burns, H. D., Wong, D. F., McPherson, R. W., Rosenbaum, A. E., Kuhar, M. J., & Snyder, S. H.
Venue
Journal of Computer Assisted Tomography
Published
1985-03
Volume
9
Issue
2
Pages
231-236
ISSN
0363-8715 (ISSN-L)
OpenAlex
W2000149891
Cited by
249
References
0
FWCI
7.26
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Imaging Opiate Receptors in the Human Brain by Positron Tomography. https://app.cochat.ai/papers/10.1097/00004728-198503000-00001
The paper
Frost, J. J., Wagner, H. N., Dannals, R. F., Ravert, H. T., Links, J. M., Wilson, A. A., Burns, H. D., Wong, D. F., McPherson, R. W., Rosenbaum, A. E., Kuhar, M. J., & Snyder, S. H. (1985). Imaging Opiate Receptors in the Human Brain by Positron Tomography. Journal of Computer Assisted Tomography. https://doi.org/10.1097/00004728-198503000-00001

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.