The DOI matches its Crossref record.
Quantitation in Positron Emission Computed Tomography: 7. A Technique to Reduce Noise in Accidental Coincidence Measurements and Coincidence Efficiency Calibration
Abstract
A method of processing accidental coincidence events (AC) and detector efficiency (DE) calibration data, which reduces the statistical noise in these measurements, and, consequently, reduces the noise in positron emission tomographic images using the technique, is described. The technique uses the fact that, in these measurements with N detectors in coincidence with N other detectors, N2 values of ACs or DEs are measured. However, these values are composed of only 2N components, which are either singles rates or individual DEs. The full set of data is used to implicitty solve for these values and the individual ACs or DEs recalculated with an improvement in statistical error equivalent to an N2/(2N + 1) increase in accumulated events for the case of a uniform distribution. This result was verified experimentally.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ollinger, J. M., & Fessler, J. A. (1997) · IEEE Signal Processing Magazine · doi:10.1109/79.560323 · Cited by 1,167
PET versus SPECT: strengths, limitations and challenges
Rahmim, A., & Zaidi, H. (2008) · Nuclear Medicine Communications · doi:10.1097/mnm.0b013e3282f3a515 · Cited by 834
Penalized weighted least-squares image reconstruction for positron emission tomography
Fessler, J. A. (1994) · IEEE Transactions on Medical Imaging · doi:10.1109/42.293921 · Cited by 611
Strother, S. C., Casey, M. E., & Hoffman, E. J. (1990) · IEEE Transactions on Nuclear Science · doi:10.1109/23.106715 · Cited by 549
Self-citationIterative reconstruction techniques in emission computed tomography
Qi, J., & Leahy, R. M. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/15/r01 · Cited by 415
Metadata
- Authors
- Casey, M. E., & Hoffman, E. J.
- Venue
- Journal of Computer Assisted Tomography
- Published
- 1986-09
- Volume
- 10
- Issue
- 5
- Pages
- 845-850
- ISSN
- 0363-8715 (ISSN-L)
- OpenAlex
- W4295679829
- Cited by
- 175
- References
- 0
- FWCI
- 2.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quantitation in Positron Emission Computed Tomography: 7. A Technique to Reduce Noise in Accidental Coincidence Measurements and Coincidence Efficiency Calibration. https://app.cochat.ai/papers/10.1097/00004728-198609000-00027
- The paper
- Casey, M. E., & Hoffman, E. J. (1986). Quantitation in Positron Emission Computed Tomography: 7. A Technique to Reduce Noise in Accidental Coincidence Measurements and Coincidence Efficiency Calibration. Journal of Computer Assisted Tomography. https://doi.org/10.1097/00004728-198609000-00027
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.