CoChat

High Signal Regions in Normal White Matter Shown by Heavily T2-Weighted CSF Nulled IR Sequences

Hajnal, Joseph V., Coene, Beatrice De, Lewis, Paul D., Baudouin, Christine J., Cowan, Frances M., Pennock, Jacqueline M., Young, Ian R., Bydder, Graeme M. · 1992 · Journal of Computer Assisted Tomography
Cited by 177

The DOI matches its Crossref record.

Abstract

Inversion recovery (IR) sequences with an inversion time (TI) designed to markedly reduce or null the signal from CSF (TI of approximately 2,100 ms at 1.0 T) and a very long echo time (TE) of 240 ms were used to image the brain of two normal adult volunteers, one 34-year-old man with an intrinsic tumor, and one 3-month-old infant with an infarct. Using these very heavily T2-weighted pulse sequences, adult gray and white matter showed similar signal intensity in many areas of the brain, but normal white matter in regions of the centrum semiovale, posterior internal capsule, parietopontile tract, occipitothalamic radiation, and brain stem showed a much higher signal intensity than surrounding gray or white matter. The infant displayed a low signal intensity in myelinated regions in the internal capsule and occipitothalamic radiation and a high signal in unmyelinated white matter. In many of the images there were strong similarities to the distribution of high signal within white matter seen with pulsed gradient spin echo sequences (TE 130 ms) designed to demonstrate effects due to anisotropic diffusion. Arguments are advanced to support the view that the high signal intensity in white matter tracts is due to one or more long T2 components that may be associated with unmyelinated or sparsely myelinated fibres within white matter. The resemblance to diffusion weighted images may reflect the fact that both employ long TEs and both produce a low signal from CSF. If myelin possessed a different susceptibility from axoplasm so that magnetic field gradients were generated around nerve fibres when their orientation was not parallel to B0, diffusion of water might then produce the observed dependence on fibre direction. The high signal regions in white matter are a potential source of confusion in image interpretation, and measurements of T2 in white matter need to be made with these regional variations in mind. The concept of normal appearing white matter also needs to be applied with a knowledge of these differences. The IR sequences used in this study provide a very high T2 dependence with a low signal from CSF and may be useful for detecting disease in the CNS of adults and children.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00004728-199207000-00002

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 177

Metadata

Authors
Hajnal, J. V., Coene, B. D., Lewis, P. D., Baudouin, C. J., Cowan, F. M., Pennock, J. M., Young, I. R., & Bydder, G. M.
Venue
Journal of Computer Assisted Tomography
Published
1992-07
Volume
16
Issue
4
Pages
506-513
ISSN
0363-8715 (ISSN-L)
OpenAlex
W2086726566
Cited by
177
References
0
FWCI
4.50
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: High Signal Regions in Normal White Matter Shown by Heavily T2-Weighted CSF Nulled IR Sequences. https://app.cochat.ai/papers/10.1097/00004728-199207000-00002
The paper
Hajnal, J. V., Coene, B. D., Lewis, P. D., Baudouin, C. J., Cowan, F. M., Pennock, J. M., Young, I. R., & Bydder, G. M. (1992). High Signal Regions in Normal White Matter Shown by Heavily T2-Weighted CSF Nulled IR Sequences. Journal of Computer Assisted Tomography. https://doi.org/10.1097/00004728-199207000-00002

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.