The DOI matches its Crossref record.
Volume of Pituitary Macroadenomas: Assessment by MRI
Abstract
A phantom study was performed to assess the accuracy of MRI in volume determination of pituitary macroadenomas, using the summation of areas technique. Five phantoms, 3-4 cm in diameter, simulating pituitary macroadenomas of various shapes, were evaluated. The volume could adequately and reproducibly be determined, regardless of minor rotational variations of the phantom position. Using a three-dimensional SE sequence with 2.5 mm slices, the error was independent of the shape of the phantom and did not differ significantly from zero (less than 5%); this sequence was found to be the best of those tested. The coefficient of variation between examinations with different tilts was 2%. In a clinical part, the volume of pituitary macroadenomas was determined with the same technique on coronal two-dimensional 5 mm images and was used as a "gold standard" to which the largest transverse, sagittal, vertical, and oblique diameters, a central tumor area, and the product of the three orthogonal diameters were correlated. In interpatient comparisons the largest diameter was found to be useful, but only as a rough measure of the tumor size. The formula 0.5 x width x length x height provided a fairly adequate estimation of the tumor volume, except in the largest tumors. In intrapatient comparisons during bromocriptine treatment, the height was found to be the best of the diameters, but the central tumor area or the product of the orthogonal diameters was preferable.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Treatment of Acromegaly with the Growth Hormone–Receptor Antagonist Pegvisomant
Trainer, P. J., Drake, W. M., Katznelson, L., Freda, P. U., Herman-Bonert, V., van der Lely, A. J., Dimaraki, E. V., Stewart, P. M., Friend, K. E., Vance, M. L., et al. (2000) · New England Journal of Medicine · doi:10.1056/nejm200004203421604 · Cited by 879
Long-term treatment of acromegaly with pegvisomant, a growth hormone receptor antagonist
van der Lely, A. J., Hutson, R. K., Trainer, P. J., Besser, G. M., Barkan, A. L., Katznelson, L., Klibanski, A., Herman-Bonert, V., Melmed, S., Vance, M. L., et al. (2001) · The Lancet · doi:10.1016/s0140-6736(01)06844-1 · Cited by 645
Wanebo, J. E., Lonser, R. R., Glenn, G. M., & Oldfield, E. H. (2003) · Journal of Neurosurgery · doi:10.3171/jns.2003.98.1.0082 · Cited by 467
The changing spectrum of TSH-secreting pituitary adenomas: diagnosis and management in 43 patients
Socin, H., Chanson, P., Delemer, B., Tabarin, A., Rohmer, V, Mockel, J., Stevenaert, A., & Beckers, A. (2003) · European Journal of Endocrinology · doi:10.1530/eje.0.1480433 · Cited by 274
Segmentation of multiple sclerosis lesions in intensity corrected multispectral MRI
Johnston, B., Atkins, M. S., Mackiewich, B., & Anderson, M. (1996) · IEEE Transactions on Medical Imaging · doi:10.1109/42.491417 · Cited by 260
Metadata
- Authors
- Lundin, P., & Pedersen, F.
- Venue
- Journal of Computer Assisted Tomography
- Published
- 1992-07
- Volume
- 16
- Issue
- 4
- Pages
- 519-528
- ISSN
- 0363-8715 (ISSN-L)
- OpenAlex
- W2035389128
- Cited by
- 198
- References
- 0
- FWCI
- 1.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Volume of Pituitary Macroadenomas: Assessment by MRI. https://app.cochat.ai/papers/10.1097/00004728-199207000-00004
- The paper
- Lundin, P., & Pedersen, F. (1992). Volume of Pituitary Macroadenomas: Assessment by MRI. Journal of Computer Assisted Tomography. https://doi.org/10.1097/00004728-199207000-00004
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.