CoChat

Reproducibility of ambulatory and clinic blood pressure measurements in elderly hypertensive subjects

Fotherby, Martin D., Potter, John F. · 1993 · Journal of Hypertension
Cited by 54

The DOI matches its Crossref record.

Abstract

OBJECTIVES: To compare the reproducibility of clinic and ambulatory blood pressure measurements in elderly hypertensive subjects. SUBJECTS: Twenty-two untreated elderly hypertensives, with a clinic systolic blood pressure (SBP) > 160 mmHg and/or diastolic blood pressure (DBP) > 95 mmHg, and a mean age of 76 years (range 66-86). METHODS: Following three supine clinic blood pressure readings the subjects underwent 24-h non-invasive ambulatory blood pressure monitoring, measurements being taken at 20-min intervals from 0700 to 2200 h and at 30-min intervals from 2200 to 0700 h. Measurements were repeated during a further visit at a median interval of 10 weeks (range 1-10 months). RESULTS: Daytime ambulatory SBP levels were 20 mmHg (95% confidence interval 14-27 mmHg, P < 0.001) lower than clinic SBP, although DBP values were similar. The mean 24-h ambulatory SBP and DBP reproducibility [assessed by the standard deviation of differences (SDD) between visits] was significantly better than that for mean clinic blood pressure (SBP 6.3 versus 17.4 mmHg, P < 0.001; DBP 4.8 versus 7.0 mmHg, respectively, P < 0.05). With daytime defined as 1000-1959 h, the SDD between visits was 12.4 mmHg for SBP and 8.3 mmHg for DBP, but with daytime defined as 0700-2159 h, the SDD fell to 6.0 mmHg for SBP and 4.8 mmHg for DBP, values almost identical to those obtained with full 24-h blood pressure monitoring. There was no difference in night-time blood pressure reproducibility, whether night-time was defined as 2400-0559 h or 2200-0659 h. CONCLUSIONS: Both 24-h and daytime ambulatory blood pressure monitoring significantly improve the reproducibility of blood pressure measurements compared with clinic blood pressure readings in elderly hypertensive subjects. Increasing the number of daytime blood pressure readings by 50% (from 30 to 45) reduced the variability of blood pressure measurement by 50%. Twenty-four-hour ambulatory blood pressure monitoring is of value in obtaining reproducible blood pressure measurements in elderly hypertensive subjects. However, more than 30 readings are needed during a daytime recording to significantly reduce variability compared with repeated clinic measurements, although night-time variability is not significantly affected if the number of readings is reduced to 12 over a 6-h period.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00004872-199305000-00014

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 54

Metadata

Authors
Fotherby, M. D., & Potter, J. F.
Venue
Journal of Hypertension
Published
1993-05
Volume
11
Issue
5
Pages
573-580
ISSN
0263-6352 (ISSN-L)
OpenAlex
W1965699133
Cited by
54
References
0
FWCI
1.24
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Reproducibility of ambulatory and clinic blood pressure measurements in elderly hypertensive subjects. https://app.cochat.ai/papers/10.1097/00004872-199305000-00014
The paper
Fotherby, M. D., & Potter, J. F. (1993). Reproducibility of ambulatory and clinic blood pressure measurements in elderly hypertensive subjects. Journal of Hypertension. https://doi.org/10.1097/00004872-199305000-00014

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.