The relationships between left ventricular mass and daytime and night-time blood pressures: a meta-analysis of comparative studies
The DOI matches its Crossref record.
Abstract
OBJECTIVE: To review the literature to examine critically the assertion that night-time blood pressure is a better predictor of echocardiographic left ventricular mass than daytime blood pressure, and that left ventricular mass is inversely related to the day-night blood pressure difference. STUDY SELECTION: Published studies in which left ventricular mass (index) of normotensive or hypertensive individuals, or both, was related to automated blood pressure measurement during the day and night, or their difference, or both. RESULTS OF DATA ANALYSIS: The meta-analysis of 19 comparative studies, involving 1223 participants, indicates that the weighted correlation coefficient for the relationship between left ventricular mass (index) and systolic night-time blood pressure (0.44; 95% confidence limit 0.39-0.48) is not significantly different from the correlation with systolic daytime blood pressure (0.48; 95% confidence limit 0.44-0.52; P > 0.2). The corresponding correlation coefficients for diastolic blood pressure both average 0.37. In half of the eight studies in which the association between left ventricular mass (index) and the day-night difference in blood pressure was analysed, investigators found no significant relationship between those variables; in the others, the variance of the mass (index) that can be explained by the blood pressure difference is 15% at the most. CONCLUSION: The overall analysis suggests that night-time blood pressure is not a significantly better predictor of left ventricular mass than daytime blood pressure is, and that the relationship to the day-night blood pressure difference is not a unanimous finding and is only ever weakly significant.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Staessen, J. A. (1999) · JAMA · doi:10.1001/jama.282.6.539 · Cited by 1,592
Self-citationPrognostic Value of Ambulatory Blood Pressure: Current Evidence and Clinical Implications
Verdecchia, P. (2000) · Hypertension · doi:10.1161/01.hyp.35.3.844 · Cited by 621
Ambulatory Blood Pressure Monitoring and Organ Damage
Mancia, G., & Parati, G. (2000) · Hypertension · doi:10.1161/01.hyp.36.5.894 · Cited by 336
Nocturnal Blood Pressure Fall on Ambulatory Monitoring in a Large International Database
Staessen, J. A., Bieniaszewski, L., O'Brien, E., Gosse, P., Hayashi, H., Imai, Y., Kawasaki, T., Otsuka, K., Palatini, P., Thijs, L., et al. (1997) · Hypertension · doi:10.1161/01.hyp.29.1.30 · Cited by 310
Self-citationImpact of Obesity on 24-Hour Ambulatory Blood Pressure and Hypertension
Kotsis, V., Stabouli, S., Bouldin, M., Low, A., Toumanidis, S., & Zakopoulos, N. (2005) · Hypertension · doi:10.1161/01.hyp.0000158261.86674.8e · Cited by 262
Metadata
- Authors
- Fagard, R., Staessen, J. A., & Thijs, L.
- Venue
- Journal of Hypertension
- Published
- 1995-08
- Volume
- 13
- Issue
- 8
- Pages
- 823-829
- ISSN
- 0263-6352 (ISSN-L)
- OpenAlex
- W2038331430
- Cited by
- 108
- References
- 0
- FWCI
- 2.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The relationships between left ventricular mass and daytime and night-time blood pressures: a meta-analysis of comparative studies. https://app.cochat.ai/papers/10.1097/00004872-199508000-00002
- The paper
- Fagard, R., Staessen, J. A., & Thijs, L. (1995). The relationships between left ventricular mass and daytime and night-time blood pressures: a meta-analysis of comparative studies. Journal of Hypertension. https://doi.org/10.1097/00004872-199508000-00002
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.