The DOI matches its Crossref record.
State of the Art Review: Techniques to Avoid Pin Loosening and Infection in External Fixation
Abstract
UNLABELLED: The purpose of this manuscript is to review techniques of optimizing the interface between the bone and pin in external fixation to minimize pin loosening and infection. CONCLUSIONS: Among the different techniques to improve the bone-pin interface in external fixation, coating the pins with hydroxyapatite proved to be the most effective. In a highly loaded animal study, three pin types were compared. Type A remained uncoated, type B was coated with hydroxyapatite, and Type C was coated with titanium. Radiographic rarefaction of the bone pin tract was lower in type B pins. Extraction torque was thirteen times higher in type B pins compared to type A and two times higher compared to type C pins. Extraction torque was significantly lower compared to the corresponding insertion torque in both types A and C. In contrast, in the hydroxyapatite coated pins there was no difference between extraction and insertion torque. At sixty times magnification, bone pin contact of type B and C pins was significantly higher than type A. At 10,000 times magnification direct bone pin contact was found only in type B pins. In a clinical study the pin insertion and extraction torque forces were measured in a study of seventy-six external fixation pins in nineteen patients treated with hemicallotasis for osteoarthritis of the medial side of the knee. The patients were randomized to be treated with either standard tapered pins or tapered pins coated with hydroxyapatite. Extraction torque of the hydroxyapatite coated pins was higher than the standard ones in both cancellous and cortical bone. These studies show that in hydroxyapatite coated pins there is no deterioration of the bone-pin interface strength and there is optimal bone-pin contact. Among the various pin types coated with hydroxyapatite, the best results were obtained with the tapered pins.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The relationship between the nanostructure of titanium surfaces and bacterial attachment
Puckett, S. D., Taylor, E., Raimondo, T., & Webster, T. J. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2009.09.081 · Cited by 683
Diagnosis and treatment of infections associated with fracture-fixation devices
Trampuz, A., & Zimmerli, W. (2006) · Injury · doi:10.1016/j.injury.2006.04.010 · Cited by 631
Studies of photokilling of bacteria using titanium dioxide nanoparticles
Tsuang, Y., Sun, J., Huang, Y., Lu, C., Chang, W. H., & Wang, C. (2008) · Artificial Organs · doi:10.1111/j.1525-1594.2007.00530.x · Cited by 247
Metadata
- Authors
- Moroni, A., Vannini, F., Mosca, M., & Giannini, S.
- Venue
- Journal of Orthopaedic Trauma
- Published
- 2002-03
- Volume
- 16
- Issue
- 3
- Pages
- 189-195
- ISSN
- 0890-5339 (ISSN-L)
- OpenAlex
- W1965507958
- Cited by
- 168
- References
- 0
- FWCI
- 4.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: State of the Art Review: Techniques to Avoid Pin Loosening and Infection in External Fixation. https://app.cochat.ai/papers/10.1097/00005131-200203000-00009
- The paper
- Moroni, A., Vannini, F., Mosca, M., & Giannini, S. (2002). State of the Art Review: Techniques to Avoid Pin Loosening and Infection in External Fixation. Journal of Orthopaedic Trauma. https://doi.org/10.1097/00005131-200203000-00009
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.