Biomechanical Evaluation of the Less Invasive Stabilization System, Angled Blade Plate, and Retrograde Intramedullary Nail for the Internal Fixation of Distal Femur Fractures
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To evaluate the stability of the retrograde intramedullary nail (IMN), angled blade plate (ABP), and a locked internal fixator (Less Invasive Stabilization System [LISS], Synthes, Paoli, PA) for internal fixation of distal femur fractures. DESIGN: Destructive biomechanical testing of matched pairs of fresh-frozen human cadaveric bone-implant constructs. SETTING: Biomechanical laboratory. METHODS: A fracture model was created to simulate an AO/OTA33-A3 fracture. Forty-eight matched pairs of specimens were used. Six groups of 8 pairs each were tested to failure: LISS versus ABP and LISS versus IMN (axial, torsional, and cyclical axial). MAIN OUTCOME MEASUREMENT: Load to failure, mode of failure, energy to failure, displacement at the load to failure, and stiffness. RESULTS: Fixation strength (load/moment to failure) of the LISS constructs was 34% greater in axial loading (P = 0.01) and 32% less in torsional loading (P = 0.05) compared with ABP constructs and 13% greater in axial loading (P = 0.35) and 45% less in torsional loading (P < 0.01) compared with IMN constructs. Loss of distal fixation in axial loading occurred in 1 of 16 cases with the LISS, in 3 of 8 cases with the ABP, and in 8 of 8 cases with the IMN. Cyclical axial loading demonstrated significantly less plastic deformation for the LISS construct compared with ABP constructs (P < 0.01) and similar plastic deformation compared with IMN constructs (P = 0.98). CONCLUSIONS: All 3 fixation devices (LISS, ABP, and IMN) offer sufficient torsional stability and sufficient proximal fixation that withstands axial loading without failing. The LISS provides improved distal fixation, especially in osteoporotic bone, at the expense of more displacement at the fracture site.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bone Compressive Strength: The Influence of Density and Strain Rate
Carter, D. R., & Hayes, W. C. (1976) · Science · doi:10.1126/science.996549 · Cited by 709
Forces and moments telemetered from two distal femoral replacements during various activities
Taylor, S. J. G., & Walker, P. S. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00042-2 · Cited by 201
Benum, P. (1977) · Acta Orthopaedica Scandinavica · doi:10.3109/17453677708985111 · Cited by 59
Cited by
Zlowodzki, M., Ayieni, O., Petrisor, B. A., & Bhandari, M. (2008) · Journal of Trauma: Injury, Infection & Critical Care · doi:10.1097/01.ta.0000241143.71274.63 · Cited by 209
Self-citation
Metadata
- Authors
- Zlowodzki, M., Williamson, S., Cole, P. A., Zardiackas, L. D., & Kregor, P. J.
- Venue
- Journal of Orthopaedic Trauma
- Published
- 2004-09
- Volume
- 18
- Issue
- 8
- Pages
- 494-502
- ISSN
- 0890-5339 (ISSN-L)
- OpenAlex
- W2066458249
- Cited by
- 268
- References
- 3
- FWCI
- 4.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Biomechanical Evaluation of the Less Invasive Stabilization System, Angled Blade Plate, and Retrograde Intramedullary Nail for the Internal Fixation of Distal Femur Fractures. https://app.cochat.ai/papers/10.1097/00005131-200409000-00004
- The paper
- Zlowodzki, M., Williamson, S., Cole, P. A., Zardiackas, L. D., & Kregor, P. J. (2004). Biomechanical Evaluation of the Less Invasive Stabilization System, Angled Blade Plate, and Retrograde Intramedullary Nail for the Internal Fixation of Distal Femur Fractures. Journal of Orthopaedic Trauma. https://doi.org/10.1097/00005131-200409000-00004
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.