The DOI matches its Crossref record.
EFFECT OF INCREASED INTRA-ABDOMINAL PRESSURE ON HEPATIC ARTERIAL, PORTAL VENOUS, AND HEPATIC MICROCIRCULATORY BLOOD FLOW
Open accessAbstract
The effects of increased intra-abdominal pressure (IAP) on hepatic perfusion were studied in five anesthetized pigs. Doppler flow probes were used to measure hepatic artery blood flow (HABF) and portal venous blood flow (PVBF), and laser Doppler flowmetry was used to assess changes in hepatic microvascular blood flow (HMVBF). Hepatic blood flow responses to 10, 20, 30 and 40 mm Hg increases in IAP were assessed while the mean arterial BP (MAP) was maintained at baseline levels with IV crystalloid infusions. Although cardiac output and MAP were normal, HABF and HMVBF fell significantly with 10 mm IAP, and at 20 mm Hg IAP, HABF was 45% of the control value, PVBF was 65% of the control value, and HMVBF was 71% of the control value (p less than 0.05). At 30 and 40 mm Hg, hepatic blood flow was reduced even more. Thus, modest increases in IAP can cause significant impairment of hepatic perfusion despite a normal BP and cardiac output.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Malbrain, M. L. N. G., Cheatham, M. L., Kirkpatrick, A., Sugrue, M., Parr, M., De Waele, J., Balogh, Z., Leppäniemi, A., Olvera, C., Ivatury, R., et al. (2006) · Intensive Care Medicine · doi:10.1007/s00134-006-0349-5 · Cited by 1,532
Malbrain, M. L. N. G., Chiumello, D., Pelosi, P., Bihari, D., Innes, R., Ranieri, V. M., Del Turco, M., Wilmer, A., Brienza, N., Malcangi, V., et al. (2005) · Critical Care Medicine · doi:10.1097/01.ccm.0000153408.09806.1b · Cited by 731
Malbrain, M. L. N. G., Chiumello, D., Pelosi, P., Wilmer, A., Brienza, N., Malcangi, V., Bihari, D., Innes, R., Cohen, J., Singer, P., et al. (2004) · Intensive Care Medicine · doi:10.1007/s00134-004-2169-9 · Cited by 565
Regulation of hepatic blood flow: The hepatic arterial buffer response revisited
Eipel, C. (2010) · World Journal of Gastroenterology · doi:10.3748/wjg.v16.i48.6046 · Cited by 560
Splanchnic Ischemia and Bacterial Translocation in the Abdominal Compartment Syndrome
Diebel, L. N., Dulchavsky, S. A., & Brown, W. J. (1997) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/00005373-199711000-00019 · Cited by 288
Self-citation
Metadata
- Authors
- Diebel, L. N., Wilson, R. F., Dulchavsky, S. A., & Saxe, J.
- Venue
- The Journal of Trauma: Injury, Infection, and Critical Care
- Published
- 1992-08
- Volume
- 33
- Issue
- 2
- Pages
- 279-283
- ISSN
- 0022-5282 (ISSN-L)
- OpenAlex
- W2053482222
- Cited by
- 405
- References
- 0
- FWCI
- 3.47
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: EFFECT OF INCREASED INTRA-ABDOMINAL PRESSURE ON HEPATIC ARTERIAL, PORTAL VENOUS, AND HEPATIC MICROCIRCULATORY BLOOD FLOW. https://app.cochat.ai/papers/10.1097/00005373-199208000-00019
- The paper
- Diebel, L. N., Wilson, R. F., Dulchavsky, S. A., & Saxe, J. (1992). EFFECT OF INCREASED INTRA-ABDOMINAL PRESSURE ON HEPATIC ARTERIAL, PORTAL VENOUS, AND HEPATIC MICROCIRCULATORY BLOOD FLOW. The Journal of Trauma: Injury, Infection, and Critical Care. https://doi.org/10.1097/00005373-199208000-00019
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.